1
00:00:00,099 --> 00:00:04,500
If you ask ten exterior cleaning
contractors across the UK how they mix their

2
00:00:04,619 --> 00:00:09,159
softwash solutions, at least six of them
will tell you some variation of the same

3
00:00:09,220 --> 00:00:09,439
thing.

4
00:00:09,939 --> 00:00:14,259
They say, oh, I just put a couple of
bucketfuls of sodium hypochlorite into a 200

5
00:00:14,299 --> 00:00:17,899
litre tank, top it up with water, add a
glug of surfactant,

6
00:00:18,000 --> 00:00:19,359
and we are good to go.

7
00:00:20,119 --> 00:00:23,999
I hear it on training courses, I see it on
social media, and honestly,

8
00:00:24,180 --> 00:00:27,479
it is one of the most expensive habits in
our entire industry.

9
00:00:28,399 --> 00:00:32,219
What people call having a feel for the mix
is usually just guessing.

10
00:00:32,639 --> 00:00:36,259
And guessing on site destroys your profit
margins, plain and simple.

11
00:00:36,452 --> 00:00:41,092
Here is what is actually happening when
you eyeball a tank mix or rely blindly on a

12
00:00:41,152 --> 00:00:42,132
basic downstreamer.

13
00:00:43,072 --> 00:00:47,532
You assume that because you poured
chemical into a barrel, you are getting a uniform

14
00:00:47,592 --> 00:00:50,852
three percent or four percent active
strength at the end of your nozzle.

15
00:00:51,833 --> 00:00:56,372
But active chemical concentration on the
wall can swing by up to 40 percent.

16
00:00:58,253 --> 00:00:58,992
40 percent.

17
00:00:59,352 --> 00:01:01,292
That is a massive margin of error.

18
00:01:02,412 --> 00:01:03,232
Why does that happen?

19
00:01:04,192 --> 00:01:08,353
Because hose length, elevation,
backpressure, ambient temperature,

20
00:01:08,652 --> 00:01:12,853
and fluid viscosity all change how liquid
moves through your system.

21
00:01:13,892 --> 00:01:18,312
If your mix is 40 percent too weak, you
get organic growth surviving,

22
00:01:18,732 --> 00:01:21,292
leading to patchy render and unpaid
callbacks.

23
00:01:22,272 --> 00:01:26,372
If it is 40 percent too strong, you are
burning through expensive chemical,

24
00:01:26,772 --> 00:01:29,752
risking plant damage, and etching
sensitive surfaces.

25
00:01:29,954 --> 00:01:30,754
Now, don't get me wrong.

26
00:01:31,214 --> 00:01:32,934
Manual batch mixing has its place.

27
00:01:33,514 --> 00:01:37,134
If you are doing a small domestic patio or
a single elevation,

28
00:01:37,614 --> 00:01:41,354
batching up a known 20 litre container
gives you reasonable control.

29
00:01:41,994 --> 00:01:44,835
You calculate your stock strength, measure
your water first,

30
00:01:45,375 --> 00:01:49,375
pour in your sodium hypochlorite, add your
bleach compatible surfactant last,

31
00:01:49,854 --> 00:01:52,014
and you know exactly what is in that
container.

32
00:01:52,975 --> 00:01:57,034
But as soon as you scale up to larger
commercial jobs or full house renders,

33
00:01:57,555 --> 00:02:00,094
batch mixing starts working against you.

34
00:02:00,135 --> 00:02:04,715
You face heavy manual handling, lifting 25
kg drums on site,

35
00:02:05,215 --> 00:02:09,334
constant downtime when the tank runs dry
mid elevation, and worst of all,

36
00:02:09,735 --> 00:02:11,014
the temptation to top up.

37
00:02:11,182 --> 00:02:14,362
Let me share a real world example of how
topping up goes wrong.

38
00:02:15,262 --> 00:02:18,382
I spoke with a contractor who was cleaning
a large rendered property.

39
00:02:18,962 --> 00:02:21,602
He started the day with a full 200 litre
batch.

40
00:02:22,162 --> 00:02:24,222
By lunchtime, the tank was about half
full.

41
00:02:24,982 --> 00:02:29,103
Instead of draining it down or carefully
calculating how many litres of water and

42
00:02:29,162 --> 00:02:32,662
concentrate were left, he simply grabbed a
container of hypochlorite,

43
00:02:33,062 --> 00:02:36,702
poured in what he thought was enough to
boost it, topped it up with a garden hose,

44
00:02:37,083 --> 00:02:38,342
and carried on spraying.

45
00:02:39,583 --> 00:02:40,142
The result?

46
00:02:40,602 --> 00:02:43,222
The chemical concentration skyrocketed mid
job.

47
00:02:43,722 --> 00:02:47,602
The upper section of the render turned
brilliant white, while the lower section had

48
00:02:47,662 --> 00:02:49,763
dark, uneven streaking.

49
00:02:49,802 --> 00:02:55,042
When the surface dried, the contractor was
hit with a 1500 pound unpaid callback to

50
00:02:55,062 --> 00:02:57,583
retreat the entire property and fix the
damage.

51
00:02:58,443 --> 00:03:01,842
All because he added a splash to a half
full tank without doing the math.

52
00:03:01,996 --> 00:03:04,736
And if you think a standard downstream
injector solves this,

53
00:03:05,276 --> 00:03:05,776
think again.

54
00:03:06,436 --> 00:03:10,276
Downstreamers introduce chemical after the
pump using venturi draw.

55
00:03:10,996 --> 00:03:14,536
They are cheap and useful for light
detergents, but they are not precise

56
00:03:14,576 --> 00:03:15,256
proportioners.

57
00:03:15,976 --> 00:03:20,156
Every time you change your nozzle, extend
your hose reel, or experience a drop in

58
00:03:20,196 --> 00:03:23,417
water pressure, your draw ratio shifts
dramatically.

59
00:03:24,136 --> 00:03:27,056
You end up applying chemical at a strength
you cannot verify,

60
00:03:27,516 --> 00:03:29,576
which brings us right back to guesswork.

61
00:03:29,787 --> 00:03:33,647
So how do high level professional
contractors eliminate this problem entirely?

62
00:03:34,527 --> 00:03:39,067
They move away from batch mixing and
downstreaming, and they shift to calibrated

63
00:03:39,227 --> 00:03:40,287
hydraulic proportioning.

64
00:03:41,128 --> 00:03:44,967
Systems like the Clever Injector Dosatron
work on a completely different principle.

65
00:03:45,687 --> 00:03:50,367
Instead of pre mixing chemical in a large
hold tank, a hydraulic dosing unit uses

66
00:03:50,407 --> 00:03:55,087
the water flow itself to power a piston
that draws pure chemical concentrate

67
00:03:55,407 --> 00:04:00,267
directly from your supply drum into the
water stream at an exact percentage ratio.

68
00:04:00,458 --> 00:04:03,018
What that means on site is massive.

69
00:04:03,138 --> 00:04:06,538
You do not carry 200 litres of mixed
chemical in your van.

70
00:04:06,638 --> 00:04:10,378
You carry fresh water and neat concentrate
in its original drum.

71
00:04:10,498 --> 00:04:14,698
The proportioner mixes on demand, only
when you pull the trigger.

72
00:04:14,911 --> 00:04:18,778
If you stop spraying, chemical consumption
stops immediately.

73
00:04:18,845 --> 00:04:22,858
There is no leftover mixed chemical
degrading in a tank at the end of the day,

74
00:04:22,898 --> 00:04:25,738
and zero wasted chemical when a job
finishes early.

75
00:04:25,849 --> 00:04:29,309
However, I have to give you a critical
piece of site reality here.

76
00:04:30,429 --> 00:04:35,069
Buying a proportioning system and turning
the dial to three percent does not

77
00:04:35,289 --> 00:04:37,909
automatically mean three percent is
landing on the wall.

78
00:04:38,869 --> 00:04:41,189
I see contractors make this mistake all
the time.

79
00:04:41,649 --> 00:04:43,709
They assume the dial setting is gospel.

80
00:04:44,309 --> 00:04:47,529
But just like with batch tanks, host hose
length, backpressure,

81
00:04:47,930 --> 00:04:51,409
and the thicker viscosity of surfactants
alter the actual draw rate.

82
00:04:52,109 --> 00:04:57,029
That is why every professional contractor
must perform a simple 60 second bucket

83
00:04:57,069 --> 00:04:58,689
draw test at the start of the day.

84
00:04:59,098 --> 00:05:00,078
It takes one minute.

85
00:05:00,818 --> 00:05:04,797
You place your chemical intake tube into a
graduated measuring jug filled with plain

86
00:05:04,898 --> 00:05:09,597
water, run your system through your full
working hose length for 60 seconds into a

87
00:05:09,657 --> 00:05:13,197
bucket, and see exactly how many
millilitres of liquid were drawn.

88
00:05:14,177 --> 00:05:17,517
If your system drew 300 millilitres into
ten litres of flow,

89
00:05:18,058 --> 00:05:20,458
you know you are running at three percent
active draw.

90
00:05:21,357 --> 00:05:24,997
If it drew 200 millilitres, you adjust
your dial and retest.

91
00:05:25,958 --> 00:05:30,257
That one minute calibration check gives
you absolute certainty before a single drop

92
00:05:30,277 --> 00:05:32,097
of chemical touches a customer property.

93
00:05:32,167 --> 00:05:36,007
When you dial in precision proportioning,
the commercial benefits hit your business

94
00:05:36,060 --> 00:05:37,527
straight away.

95
00:05:37,580 --> 00:05:42,327
First, you cut chemical waste by up to 25
percent because you are never over

96
00:05:42,380 --> 00:05:44,807
applying or throwing away stale batches.

97
00:05:44,956 --> 00:05:49,687
Second, your COSHH compliance and
paperwork become effortless because you can

98
00:05:49,740 --> 00:05:54,167
document exact application strengths for
site surveys and RAMS documents.

99
00:05:54,307 --> 00:05:59,047
And third, it completely separates you
from splash and dash operators who are

100
00:05:59,091 --> 00:06:02,407
guessing their way through jobs and
risking costly damage.

101
00:06:02,417 --> 00:06:06,737
If you want to raise your standards and
master the real science behind exterior

102
00:06:06,773 --> 00:06:10,737
cleaning chemistry, equipment setup, and
surface identification,

103
00:06:10,785 --> 00:06:15,777
take a look at our CPD Certified Softwash
Training Course at softwashing.uk.

104
00:06:15,897 --> 00:06:20,577
Whether you are upgrading your rig or
starting fresh, getting your chemistry and

105
00:06:20,617 --> 00:06:24,337
equipment calibrated is the fastest way to
build a profitable,

106
00:06:24,380 --> 00:06:25,897
professional business.

107
00:06:25,985 --> 00:06:30,817
Take the time to run your bucket test on
your next job, stop guessing your mixes,

108
00:06:30,857 --> 00:06:33,297
and I will see you on the next episode.