1
00:00:00,159 --> 00:00:05,079
You are standing in front of a stubborn
rendered wall, and nothing is happening.

2
00:00:05,619 --> 00:00:09,199
The organic staining, the red algae, the
black biological spots,

3
00:00:09,719 --> 00:00:10,800
they are just sitting there.

4
00:00:11,380 --> 00:00:12,099
So what do you do?

5
00:00:12,840 --> 00:00:16,100
The natural reaction for a lot of
contractors, especially when they are starting

6
00:00:16,159 --> 00:00:19,179
out, is to assume the algae must be
resistant.

7
00:00:19,219 --> 00:00:20,139
They double down.

8
00:00:20,399 --> 00:00:23,699
They turn the dial up from a two percent
mix to a four percent mix,

9
00:00:23,979 --> 00:00:25,500
or even a five percent mix.

10
00:00:26,159 --> 00:00:27,079
But here is the thing.

11
00:00:27,739 --> 00:00:30,939
The issue usually is not the algae at all.

12
00:00:31,000 --> 00:00:33,000
The issue is sitting in the back of your
van.

13
00:00:33,042 --> 00:00:36,642
I see this happen all the time,
particularly during the warmer summer months.

14
00:00:36,722 --> 00:00:40,882
A contractor buys a drum of standard
fourteen percent sodium hypochlorite.

15
00:00:41,042 --> 00:00:44,882
It sits in the back of a hot van for three
weeks where temperatures easily hit

16
00:00:44,928 --> 00:00:46,162
twenty five degrees C.

17
00:00:46,322 --> 00:00:50,562
And without them realizing it, that
fourteen percent stock chemical has degraded

18
00:00:50,594 --> 00:00:52,722
down to six percent, or even lower.

19
00:00:52,935 --> 00:00:57,602
So when you think you are applying a
potent two percent working mix to that render,

20
00:00:57,622 --> 00:01:01,202
you are actually spraying little more than
weak, salty water.

21
00:01:01,342 --> 00:01:05,202
And no matter how long you let it dwell,
it is just not going to break down that

22
00:01:05,302 --> 00:01:06,002
biofilm.

23
00:01:06,099 --> 00:01:09,019
To understand why this happens, you have
to look at the chemistry of sodium

24
00:01:09,099 --> 00:01:09,759
hypochlorite.

25
00:01:10,339 --> 00:01:12,599
It is an inherently unstable compound.

26
00:01:13,159 --> 00:01:17,519
Exposure to heat, UV sunlight, and air
exposure accelerates the natural

27
00:01:17,619 --> 00:01:18,859
decomposition process.

28
00:01:19,299 --> 00:01:23,260
The chemical literally breaks down into
sodium chloride, which is just standard

29
00:01:23,319 --> 00:01:25,000
salt, and oxygen gas.

30
00:01:25,619 --> 00:01:29,840
According to industry guidance on chemical
stability, sodium hypochlorite degrades

31
00:01:29,920 --> 00:01:32,979
over time, particularly when exposed to
heat and sunlight.

32
00:01:33,619 --> 00:01:37,940
In warm summer conditions, your stock
chemical strength can easily drop by twenty to

33
00:01:37,979 --> 00:01:41,180
thirty percent over a couple of weeks if
it is not stored correctly.

34
00:01:41,375 --> 00:01:43,455
I, I learned this lesson the hard way
years ago.

35
00:01:43,695 --> 00:01:47,615
I was out on a large residential render
job early in my career.

36
00:01:47,815 --> 00:01:50,975
I had a batch of stock chemical that had
been sitting around for a while in the

37
00:01:51,023 --> 00:01:51,295
heat.

38
00:01:51,575 --> 00:01:55,775
I mixed it up to what I thought was my
usual reliable percentage,

39
00:01:55,825 --> 00:01:58,335
applied it to the elevation, and...

40
00:01:58,385 --> 00:01:58,895
nothing.

41
00:01:58,975 --> 00:02:00,575
The black spots barely faded.

42
00:02:00,895 --> 00:02:05,295
I thought, well, maybe I did not use
enough surfactant, or maybe the render is super

43
00:02:05,375 --> 00:02:05,935
porous.

44
00:02:06,148 --> 00:02:10,415
So I mixed another batch, thicker and
stronger, applied it again,

45
00:02:10,461 --> 00:02:12,015
waited another thirty minutes.

46
00:02:12,255 --> 00:02:17,295
I wasted over two hours on that single
elevation, re-treating and re-applying,

47
00:02:17,352 --> 00:02:20,015
purely because my raw ingredient had lost
its punch.

48
00:02:20,175 --> 00:02:24,415
It was a massive wake up call for me on
why fresh chemical and controlled dilution

49
00:02:24,535 --> 00:02:28,335
are completely non-negotiable if you want
to run a profitable business.

50
00:02:28,412 --> 00:02:32,372
And operating on guesswork like that does
serious damage to your business margins.

51
00:02:32,972 --> 00:02:36,252
When you blindly ramp up volume to
compensate for weak chemical,

52
00:02:36,652 --> 00:02:38,872
you spill over into all kinds of problems.

53
00:02:39,312 --> 00:02:43,092
First, you are throwing away money on
wasted chemical spend.

54
00:02:43,713 --> 00:02:47,192
Second, when that over-applied mix finally
dries on the render,

55
00:02:47,712 --> 00:02:52,013
all that extra salt content can cause
white salt bloom efflorescence on the surface,

56
00:02:52,452 --> 00:02:54,572
which is a nightmare to rectify.

57
00:02:55,212 --> 00:03:00,152
And third, unmeasured, heavy runoff
increases the risk of plant scorching in the

58
00:03:00,212 --> 00:03:01,312
customer's flowerbeds.

59
00:03:02,052 --> 00:03:05,552
All because nobody checked the actual
strength of the stock drum in the morning.

60
00:03:05,871 --> 00:03:10,051
So how do we fix this and take complete
control of our chemistry on site?

61
00:03:10,951 --> 00:03:13,351
It starts with basic storage practice.

62
00:03:13,991 --> 00:03:18,271
You should always store your sodium
hypochlorite in UV opaque containers,

63
00:03:18,672 --> 00:03:22,491
keeping the drums upright with vented
caps, tucked away in a cool,

64
00:03:22,771 --> 00:03:24,891
shaded area of your vehicle or unit.

65
00:03:25,511 --> 00:03:30,391
And, er, this is a massive health and
safety point, you must keep hypochlorite

66
00:03:30,451 --> 00:03:36,191
completely isolated from any acidic
products, like rust removers or descalers.

67
00:03:36,931 --> 00:03:41,891
Mixing acids with sodium hypochlorite
releases toxic chlorine gas instantly,

68
00:03:42,531 --> 00:03:47,292
so proper chemical segregation in your van
is an absolute priority under COSHH

69
00:03:47,332 --> 00:03:47,731
duties.

70
00:03:47,891 --> 00:03:50,931
Now, how do you eliminate the guesswork on
site?

71
00:03:51,631 --> 00:03:53,331
It is actually remarkably simple.

72
00:03:53,871 --> 00:03:58,612
A basic hydrometer test or a quick
chemical titration check allows you to verify the

73
00:03:58,752 --> 00:04:03,671
exact strength of your stock chemical in
thirty seconds before you mix a single

74
00:04:03,771 --> 00:04:04,031
drop.

75
00:04:04,911 --> 00:04:08,472
If you know your stock is sitting at ten
percent instead of fourteen percent,

76
00:04:08,972 --> 00:04:13,311
you can adjust your water ratio accurately
to achieve your target percentage on the

77
00:04:13,371 --> 00:04:13,651
wall.

78
00:04:14,451 --> 00:04:19,212
Alternatively, using continuous inline
dosing systems or sourcing fresh,

79
00:04:19,571 --> 00:04:23,891
high grade products like Soft Wash Pro 50
ensures you get consistent,

80
00:04:23,951 --> 00:04:28,611
reliable active percentages every single
time you pull the trigger on vertical

81
00:04:28,652 --> 00:04:28,951
render.

82
00:04:29,000 --> 00:04:33,160
This level of chemical understanding is
what genuinely separates professional,

83
00:04:33,230 --> 00:04:37,880
trusted softwashing contractors from
splash and dash operators who just guess and

84
00:04:37,960 --> 00:04:38,920
hope for the best.

85
00:04:39,080 --> 00:04:43,080
When you know your chemistry, you protect
your customer's property,

86
00:04:43,140 --> 00:04:47,400
you safeguard nearby planting, and you
protect your own profit margins.

87
00:04:47,667 --> 00:04:50,760
If you want to deepen your knowledge on
softwash chemistry,

88
00:04:50,810 --> 00:04:55,480
surface identification, and safe
application methods, I invite you to check out our

89
00:04:55,560 --> 00:05:01,640
SoftWash UK CPD Certified Softwash
Training Course over at softwashing.uk.

90
00:05:01,880 --> 00:05:06,840
It is designed specifically to give UK
contractors the practical confidence and

91
00:05:06,909 --> 00:05:10,280
formal accreditation needed to excel in
this industry.

92
00:05:10,491 --> 00:05:14,792
Before you head out on your next job this
week, take two minutes to check the age

93
00:05:14,851 --> 00:05:19,112
and storage conditions of your stock
chemical, especially if the weather is heating

94
00:05:19,172 --> 00:05:19,311
up.

95
00:05:20,132 --> 00:05:24,091
Test your mixes, respect the chemistry,
and keep your standards high.

96
00:05:24,831 --> 00:05:28,052
Until next time, stay safe and keep
cleaning smarter.