1
00:00:00,120 --> 00:00:04,540
You know, I, I see this happen week in,
week out across the UK exterior cleaning

2
00:00:04,580 --> 00:00:07,080
trade, and frankly, it just breaks my
heart.

3
00:00:07,120 --> 00:00:10,140
A contractor gets called out to a lovely
red brick property,

4
00:00:10,340 --> 00:00:13,560
maybe a brand new build or a recently
repointed wall.

5
00:00:14,080 --> 00:00:18,370
The customer points to this white, dusty
crust spreading across the masonry,

6
00:00:18,920 --> 00:00:24,260
and the contractor immediately thinks, ah,
easy job, that is just white lichen or

7
00:00:24,360 --> 00:00:25,890
severe biological growth.

8
00:00:26,560 --> 00:00:27,590
So what do they do?

9
00:00:27,620 --> 00:00:31,790
They go straight to their van, pump up a
heavy mix of sodium hypochlorite,

10
00:00:32,210 --> 00:00:35,350
throw in a load of expensive surfactant,
and spray the wall down.

11
00:00:35,980 --> 00:00:37,980
And then...

12
00:00:38,060 --> 00:00:39,030
absolute silence.

13
00:00:39,800 --> 00:00:40,680
Nothing happens.

14
00:00:41,250 --> 00:00:42,660
The white marks do not budge.

15
00:00:43,140 --> 00:00:47,470
If anything, once the brickwork dries back
out, the white crust looks even brighter

16
00:00:47,480 --> 00:00:49,320
and worse than before.

17
00:00:49,380 --> 00:00:51,760
That right there is the sodium
hypochlorite trap.

18
00:00:52,128 --> 00:00:56,028
The, the reason bleach completely fails in
this scenario comes down to basic

19
00:00:56,048 --> 00:00:56,508
chemistry.

20
00:00:57,168 --> 00:00:59,928
What you are looking at is not organic
growth at all.

21
00:01:00,248 --> 00:01:01,428
It is efflorescence.

22
00:01:02,108 --> 00:01:05,728
As moisture moves through porous clay
bricks and mortar joints,

23
00:01:05,788 --> 00:01:10,088
it dissolves internal mineral salts,
things like sodium sulphate and calcium

24
00:01:10,148 --> 00:01:10,668
carbonate.

25
00:01:11,368 --> 00:01:15,278
When that moisture reaches the outer face
of the brick and evaporates into the air,

26
00:01:15,788 --> 00:01:20,088
it leaves those heavy mineral salts behind
as a hard crystalline crust.

27
00:01:20,628 --> 00:01:23,888
Now, sodium hypochlorite is an oxidiser.

28
00:01:23,928 --> 00:01:27,388
It is fantastic for breaking down organic
matter like green algae,

29
00:01:27,788 --> 00:01:30,248
black fungi, or lichen spores.

30
00:01:30,268 --> 00:01:34,148
But it cannot oxidise mineral salts or
dissolve calcium carbonate.

31
00:01:34,658 --> 00:01:38,718
You can dump gallons of pure sodium
hypochlorite onto a salt bloom,

32
00:01:38,728 --> 00:01:42,848
and all you are doing is wasting expensive
chemical, soaking the brick in extra

33
00:01:42,948 --> 00:01:48,048
water, and setting yourself up for a very
embarrassing, very costly call back when

34
00:01:48,088 --> 00:01:50,208
the customer sees zero improvement.

35
00:01:50,538 --> 00:01:55,758
And then comes the second massive mistake
contractors make when bleach fails.

36
00:01:55,798 --> 00:01:58,018
They pull out a steel wire brush.

37
00:01:59,818 --> 00:02:04,388
I, I cannot tell you how many times I have
seen people try to manually scrub those

38
00:02:04,438 --> 00:02:10,078
powdery white salt crusts off soft UK clay
bricks with a wire brush.

39
00:02:10,118 --> 00:02:12,458
It seems logical on the surface, right?

40
00:02:12,468 --> 00:02:15,178
Mechanically scrape off the hard deposit.

41
00:02:15,218 --> 00:02:18,348
But soft clay bricks are extremely
abrasive to metal.

42
00:02:18,958 --> 00:02:23,778
As you drag that steel wire brush across
the face, microscopic iron particles break

43
00:02:23,858 --> 00:02:27,558
off and get trapped inside the tiny pores
of the brick face.

44
00:02:27,618 --> 00:02:30,218
Everything looks alright for about forty
eight hours.

45
00:02:30,258 --> 00:02:34,848
Then the first rain shower hits, those
trapped iron particles react with oxygen and

46
00:02:34,898 --> 00:02:39,458
moisture, and suddenly your customer calls
you up furious because their wall has

47
00:02:39,518 --> 00:02:44,688
turned from a white powdery salt issue
into permanent, bright orange rust streaks.

48
00:02:45,358 --> 00:02:50,298
You have literally turned a simple salt
issue into structural staining that requires

49
00:02:50,338 --> 00:02:52,878
heavy acid restoration to fix.

50
00:02:52,937 --> 00:02:55,957
So how do you avoid falling into this trap
in the first place?

51
00:02:55,996 --> 00:03:00,737
Well, I always teach contractors to use my
sixty second spot test before even

52
00:03:00,797 --> 00:03:02,917
touching a chemical tank valve.

53
00:03:02,957 --> 00:03:03,957
It is dead simple.

54
00:03:04,737 --> 00:03:09,177
Take a tiny drop of a mild acidic cleaner,
or even plain household white vinegar

55
00:03:09,197 --> 00:03:13,437
from your lunch kit, and drop it directly
onto the white deposit.

56
00:03:13,477 --> 00:03:14,887
Watch what happens closely.

57
00:03:15,677 --> 00:03:18,937
If the white mark is biological, like a
stubborn white lichen,

58
00:03:19,397 --> 00:03:23,877
the vinegar will just sit there or soak in
slowly with no real reaction.

59
00:03:23,897 --> 00:03:27,097
But if that white crust is calcium
carbonate efflorescence,

60
00:03:27,637 --> 00:03:31,997
the acid will instantly start to fizz and
bubble gently as it reacts with the

61
00:03:32,037 --> 00:03:32,917
alkaline salt.

62
00:03:33,677 --> 00:03:36,857
In less than one minute, without spending
a penny on stock chemical,

63
00:03:37,437 --> 00:03:40,507
you know exactly what substrate and stain
you are dealing with,

64
00:03:40,957 --> 00:03:44,317
and you can pick the right product for the
job every single time.

65
00:03:44,683 --> 00:03:48,793
Once you have identified efflorescence,
you have to shift your mindset entirely away

66
00:03:48,823 --> 00:03:53,163
from sodium hypochlorite and move over to
a safe acid workflow.

67
00:03:53,183 --> 00:03:57,883
But working with acids on brickwork comes
with a nonnegotiable golden rule that so

68
00:03:57,903 --> 00:03:59,883
many contractors skip out of sheer rush.

69
00:04:00,703 --> 00:04:06,163
You must pre wet the brickwork thoroughly
with clean water before any chemical

70
00:04:06,263 --> 00:04:07,603
touches the wall.

71
00:04:07,703 --> 00:04:09,103
I cannot stress this enough.

72
00:04:09,623 --> 00:04:13,183
Dry clay bricks and mortar joints act like
giant sponges.

73
00:04:13,903 --> 00:04:18,863
If you spray acidic cleaner onto dry
masonry, the substrate sucks the concentrated

74
00:04:18,963 --> 00:04:21,423
chemical deep into its internal pore
structure.

75
00:04:22,123 --> 00:04:26,433
That acid gets trapped inside, where it
starts aggressively eroding the lime mortar,

76
00:04:26,923 --> 00:04:31,203
weakening the structural bond, and
actually pushing soluble salts deeper into the

77
00:04:31,223 --> 00:04:34,843
substrate only for them to bloom back out
later.

78
00:04:34,863 --> 00:04:39,583
By soaking the wall with clean water
first, you fill those internal pores.

79
00:04:39,643 --> 00:04:43,873
That keeps the active acid sitting right
on the surface where the salt crust is,

80
00:04:43,923 --> 00:04:47,172
letting it do its job without destroying
the building materials underneath.

81
00:04:48,142 --> 00:04:52,022
Now, let us talk about chemical selection,
because this is where a lot of

82
00:04:52,062 --> 00:04:54,482
traditional builders get it dead wrong.

83
00:04:54,582 --> 00:04:57,752
For decades, people have just thrown raw
hydrochloric acid,

84
00:04:58,162 --> 00:05:00,982
what people call standard brick acid, at
masonry.

85
00:05:02,202 --> 00:05:04,802
Raw hydrochloric acid is far too
aggressive.

86
00:05:05,322 --> 00:05:08,902
It etches delicate brick faces, destroys
historical mortar,

87
00:05:09,362 --> 00:05:13,342
and if you get a tiny bit of overspray on
nearby aluminium window frames or door

88
00:05:13,422 --> 00:05:17,662
trim, it will permanently pit and corrode
the metalwork within seconds.

89
00:05:18,442 --> 00:05:23,262
Instead, professional softwashers use
controlled, mild organic acid chemistry,

90
00:05:23,882 --> 00:05:27,482
usually buffered formulations sitting
around five to ten percent strength.

91
00:05:28,212 --> 00:05:32,702
These buffered products break down the
salt crusts smoothly without burning the clay

92
00:05:32,742 --> 00:05:36,052
face or causing catastrophic damage to
surrounding fixtures.

93
00:05:36,288 --> 00:05:40,528
The application technique itself requires
patience and mechanical empathy.

94
00:05:41,428 --> 00:05:45,848
You want to work in short, controlled
dwell cycles, usually around eight to ten

95
00:05:45,908 --> 00:05:46,808
minutes per section.

96
00:05:47,608 --> 00:05:51,408
Apply your mild acidic solution, let it
react with the salt crust,

97
00:05:51,788 --> 00:05:56,307
and then agitate the surface gently using
a stiff nylon broom or nylon brush.

98
00:05:57,388 --> 00:05:59,668
Notice I said nylon, never wire!

99
00:06:00,398 --> 00:06:04,668
The nylon bristles help loosen the
softened mineral deposits without scratching the

100
00:06:04,688 --> 00:06:06,328
brick or leaving metal behind.

101
00:06:07,588 --> 00:06:11,808
After your dwell time, flush the entire
elevation down thoroughly with low pressure

102
00:06:11,848 --> 00:06:13,008
water.

103
00:06:13,068 --> 00:06:17,337
You do not need massive pressure washers
blasting at three thousand pounds per

104
00:06:17,388 --> 00:06:18,808
square inch here.

105
00:06:18,868 --> 00:06:23,378
High pressure will just damage fragile
mortar joints and blow water deep into the

106
00:06:23,408 --> 00:06:25,028
cavity wall.

107
00:06:25,128 --> 00:06:29,908
Low pressure rinsing clears the
neutralised chemical and dissolved salts safely.

108
00:06:31,478 --> 00:06:35,848
Finally, you have to manage client
expectations and address the root cause of the

109
00:06:35,898 --> 00:06:36,318
moisture.

110
00:06:37,438 --> 00:06:40,738
Chemical cleaning removes the surface salt
bloom that is currently visible,

111
00:06:41,218 --> 00:06:44,018
but chemistry cannot fix a structural
water leak!

112
00:06:45,018 --> 00:06:48,578
If the property has a leaking gutter
overhead, a cracked downpipe,

113
00:06:48,878 --> 00:06:52,018
or a failed damp proof course allowing
ground water ingress,

114
00:06:52,598 --> 00:06:57,038
those internal salts will simply keep
dissolving and migrating back to the surface

115
00:06:57,078 --> 00:06:58,018
as the wall dries.

116
00:06:59,158 --> 00:07:02,858
As a professional contractor, your job is
to educate the property owner.

117
00:07:03,678 --> 00:07:07,698
Point out the leaking gutter joint,
explain why the moisture is driving the salt

118
00:07:07,778 --> 00:07:12,538
movement, and clarify that fixing the
water source is the only way to stop the bloom

119
00:07:12,638 --> 00:07:13,778
coming back long term.

120
00:07:14,853 --> 00:07:18,193
If you want to master surface
identification, chemical safety,

121
00:07:18,473 --> 00:07:22,653
and proper job site workflow, take a look
at what we offer at SoftWash UK.

122
00:07:23,793 --> 00:07:28,583
Our CPD Certified Softwash Training Course
gives you the hands on confidence and

123
00:07:28,633 --> 00:07:33,513
technical foundation you need, supported
by hundreds of free articles and guides in

124
00:07:33,553 --> 00:07:35,363
the SoftWash UK Knowledge Centre.

125
00:07:36,473 --> 00:07:41,193
It is the clearest pathway to building a
reputable business and becoming an Approved

126
00:07:41,253 --> 00:07:43,673
Softwash Applicator.

127
00:07:43,713 --> 00:07:47,783
Thanks for listening today, keep your
standards high, work safe out there,

128
00:07:47,793 --> 00:07:49,063
and I will catch you on the next one.