1
00:00:00,140 --> 00:00:03,380
A customer rings you about grey tracks
running down their render,

2
00:00:03,820 --> 00:00:05,260
right underneath the lead flashing.

3
00:00:06,160 --> 00:00:10,340
You turn up, mix a nice batch of sodium
hypochlorite, and spray the wall.

4
00:00:12,280 --> 00:00:13,560
And the stain doesn't move.

5
00:00:14,180 --> 00:00:15,980
In fact, it can look worse.

6
00:00:17,600 --> 00:00:21,180
I've seen that happen more than once, and
today I want to explain why.

7
00:00:21,412 --> 00:00:26,612
I'm Mark Cave from SoftWash UK, and this
episode is all about lead staining on

8
00:00:26,672 --> 00:00:26,992
render.

9
00:00:27,872 --> 00:00:32,512
If you listened to the recent episodes on
red stains and why bleach fails on rust,

10
00:00:33,072 --> 00:00:34,772
this is the next piece of that puzzle.

11
00:00:35,332 --> 00:00:36,912
Same lesson, different metal.

12
00:00:37,307 --> 00:00:39,387
First, what are you actually looking at?

13
00:00:40,047 --> 00:00:43,747
Lead run off usually shows up as stubborn
grey, dark charcoal,

14
00:00:43,887 --> 00:00:46,327
black or even chalky white tracks.

15
00:00:46,907 --> 00:00:50,267
They run vertically, directly beneath lead
flashings, aprons,

16
00:00:50,607 --> 00:00:53,427
dormer cheeks, window cills and chimney
abutments.

17
00:00:54,827 --> 00:00:57,947
If the stain starts at a piece of lead and
ends at the ground,

18
00:00:58,427 --> 00:00:59,847
that's your first big clue.

19
00:01:00,183 --> 00:01:00,963
Now the mechanism.

20
00:01:01,623 --> 00:01:04,503
New lead, or lead that hasn't developed
its natural patina,

21
00:01:04,903 --> 00:01:07,563
reacts with moisture and carbon dioxide in
the air.

22
00:01:08,603 --> 00:01:11,563
That forms lead carbonate and lead oxides.

23
00:01:12,223 --> 00:01:14,763
Rain then washes those metallic salts down
the wall.

24
00:01:15,283 --> 00:01:16,503
And render is porous.

25
00:01:16,923 --> 00:01:21,543
Monocouche, silicone, painted render, it
doesn't matter, those mineral particles get

26
00:01:21,603 --> 00:01:23,503
pulled into the pores and sit there.

27
00:01:24,843 --> 00:01:25,923
That's why it's so stubborn.

28
00:01:26,513 --> 00:01:28,933
So why does sodium hypochlorite fail?

29
00:01:29,473 --> 00:01:32,613
Because it's an oxidiser designed for
living things.

30
00:01:33,213 --> 00:01:34,893
Algae, mould, lichen.

31
00:01:35,673 --> 00:01:37,133
Lead salts aren't alive.

32
00:01:37,833 --> 00:01:39,733
Bleach has nothing to break down.

33
00:01:40,933 --> 00:01:45,253
Worse, if hypo lands on the lead itself,
or on unrinsed lead run off,

34
00:01:45,713 --> 00:01:47,413
it oxidises the metal rapidly.

35
00:01:48,013 --> 00:01:52,173
The flashing turns dark orange, even
chocolate brown, and that stain can set.

36
00:01:53,653 --> 00:01:56,953
I've seen contractors keep adding more
strength, thinking it's a stronger mix

37
00:01:56,973 --> 00:01:57,293
problem.

38
00:01:57,933 --> 00:01:58,433
It's not.

39
00:01:59,133 --> 00:02:00,253
It's the wrong chemistry.

40
00:02:00,620 --> 00:02:04,200
What does work is reducing, chelating acid
chemistry.

41
00:02:04,420 --> 00:02:08,160
Oxalic acid based products dissolve and
bind those metallic salts,

42
00:02:08,619 --> 00:02:10,200
and that releases them from the render.

43
00:02:10,720 --> 00:02:13,040
It's the same family of thinking you use
for rust weeping.

44
00:02:15,100 --> 00:02:18,540
Different stain, but you reach for acid
chemistry rather than bleach.

45
00:02:19,083 --> 00:02:21,323
Now the safety rule, and I won't soften
it.

46
00:02:21,803 --> 00:02:24,663
Never mix an acid with sodium
hypochlorite.

47
00:02:26,483 --> 00:02:27,863
You get toxic chlorine gas.

48
00:02:28,323 --> 00:02:30,963
That includes oxalic acid and lead stain
removers.

49
00:02:31,383 --> 00:02:34,483
Separate buckets, separate pumps, separate
hoses.

50
00:02:35,043 --> 00:02:37,883
And if you've washed the wall with hypo,
rinse it thoroughly,

51
00:02:37,923 --> 00:02:41,283
with no residual bleach left, before any
acid goes on.

52
00:02:41,660 --> 00:02:42,800
Here's the workflow I'd teach.

53
00:02:43,240 --> 00:02:44,020
Start at the survey.

54
00:02:44,340 --> 00:02:44,700
Look up.

55
00:02:45,300 --> 00:02:47,560
Check the lead above the stained
elevation.

56
00:02:47,820 --> 00:02:49,880
Is there a flashing, an apron, a cill?

57
00:02:50,560 --> 00:02:53,620
Ask whether the lead was treated with
patination oil when it was installed,

58
00:02:53,960 --> 00:02:56,960
because that oil is there to stop the
carbonate run off in the first place.

59
00:02:57,540 --> 00:02:59,780
Photograph everything before you touch it.

60
00:02:59,913 --> 00:03:00,753
Then sequence.

61
00:03:01,373 --> 00:03:06,033
Lead and rust stains should ideally be
assessed and treated before you apply your

62
00:03:06,073 --> 00:03:07,673
general biocide or hypo mix.

63
00:03:08,333 --> 00:03:12,833
Or, if you've done the full chemical wash,
only once the surface is completely

64
00:03:12,873 --> 00:03:13,913
rinsed and dry.

65
00:03:15,733 --> 00:03:18,073
Don't let the two chemistries meet on the
wall.

66
00:03:18,327 --> 00:03:20,007
Test patch, every time.

67
00:03:20,627 --> 00:03:23,487
Acid can over brighten coloured monocouche
or mineral render,

68
00:03:23,627 --> 00:03:25,387
so pick an inconspicuous spot.

69
00:03:26,067 --> 00:03:26,947
Watch your dwell time.

70
00:03:27,307 --> 00:03:28,607
Don't let it dry on the surface.

71
00:03:29,027 --> 00:03:32,767
Feather the edges so you don't leave a
halo, a clean looking patch with a ring

72
00:03:32,807 --> 00:03:33,227
around it.

73
00:03:34,587 --> 00:03:36,667
Then rinse with plenty of low pressure
water.

74
00:03:37,327 --> 00:03:40,747
And check it when it's dry, because wet
render always flatters you.

75
00:03:40,997 --> 00:03:42,517
What if you've already scorched the lead?

76
00:03:43,117 --> 00:03:43,657
It happens.

77
00:03:44,237 --> 00:03:47,277
Bleach drifts onto a flashing during a
roof or render wash,

78
00:03:47,617 --> 00:03:49,317
and the lead goes brown or orange.

79
00:03:50,357 --> 00:03:54,757
Our Lead X Pro is a ready to use lead
stain remover made for exactly that.

80
00:03:55,517 --> 00:03:59,757
It's designed to reverse that brown
oxidisation and bring back the natural grey

81
00:03:59,837 --> 00:04:00,297
patina.

82
00:04:01,177 --> 00:04:05,177
Coverage is around four to five square
metres per litre, and you rinse thoroughly

83
00:04:05,277 --> 00:04:05,797
afterwards.

84
00:04:07,617 --> 00:04:09,017
Prevention is better, of course.

85
00:04:09,537 --> 00:04:11,917
Wet and protect the lead before you spray
near it.

86
00:04:12,078 --> 00:04:13,398
Now the part people skip.

87
00:04:13,998 --> 00:04:14,658
Source control.

88
00:04:15,438 --> 00:04:19,898
If you clean the wall but the lead keeps
weathering, rain will wash fresh salts down

89
00:04:19,958 --> 00:04:20,918
and you'll get a callback.

90
00:04:22,618 --> 00:04:24,098
So tell the owner honestly.

91
00:04:24,758 --> 00:04:28,538
Clean the lead, and coat it with
patination oil, so the surface is sealed.

92
00:04:29,198 --> 00:04:31,818
Thin, even film, on clean, dry metal.

93
00:04:32,538 --> 00:04:34,078
That's how you stop the stain coming back.

94
00:04:34,348 --> 00:04:37,568
And this is why I keep saying softwashing
is a technical trade.

95
00:04:38,208 --> 00:04:40,548
Surface science, chemistry, diagnosis.

96
00:04:40,848 --> 00:04:42,708
Not just splashing bleach about.

97
00:04:43,248 --> 00:04:46,208
Knowing it's lead and not algae saves the
job.

98
00:04:46,372 --> 00:04:49,872
A podcast is a great starting point, but
if you want the depth,

99
00:04:50,232 --> 00:04:55,392
the SoftWash UK CPD Certified Softwash
Training Course covers chemical selection,

100
00:04:55,892 --> 00:05:00,952
surface identification, safety and
pricing, at your own pace online.

101
00:05:01,632 --> 00:05:05,232
Complete it and you can become an Approved
Softwash Applicator,

102
00:05:05,732 --> 00:05:09,912
get a directory listing, and join the
National Association of Softwash community.

103
00:05:10,592 --> 00:05:12,532
Have a look at softwashing.uk.

104
00:05:12,705 --> 00:05:13,365
Here's a challenge.

105
00:05:13,905 --> 00:05:17,365
Next time you're on a survey, look up
before you look at the wall.

106
00:05:18,005 --> 00:05:19,125
Find the metal first.

107
00:05:19,825 --> 00:05:21,565
Take care, and speak to you again soon.