1
00:00:00,200 --> 00:00:04,045
Most of the time, when a softwash job goes
wrong, it isn't the chemical's fault.

2
00:00:05,667 --> 00:00:06,488
It's the delivery.

3
00:00:07,169 --> 00:00:10,252
The contractor simply didn't know what
strength was really hitting the wall.

4
00:00:11,454 --> 00:00:15,399
I'm Mark Cave from SoftWash UK, and today
we're comparing batch mixing with

5
00:00:15,439 --> 00:00:16,380
proportioning systems.

6
00:00:16,577 --> 00:00:17,598
Here's where it goes wrong.

7
00:00:18,219 --> 00:00:19,621
You've got a tank that's half empty.

8
00:00:20,241 --> 00:00:23,905
You tip some more hypo in by eye, top up
with water, and off you go.

9
00:00:24,606 --> 00:00:26,028
That next batch is a guess.

10
00:00:26,628 --> 00:00:31,113
Do that a few times and the concentration
can swing by as much as forty percent.

11
00:00:31,113 --> 00:00:34,137
That's the difference between a clean wall
and a damaged one.

12
00:00:34,455 --> 00:00:37,880
So let's start with batch mixing, because
everyone should master it first.

13
00:00:38,881 --> 00:00:39,582
The order matters.

14
00:00:39,982 --> 00:00:43,527
Water in the tank first, then your
concentrate, then surfactant last.

15
00:00:44,008 --> 00:00:45,750
Water first reduces splash risk.

16
00:00:46,030 --> 00:00:49,034
Surfactant last stops the tank foaming up
like a bubble bath.

17
00:00:49,663 --> 00:00:50,864
The formula is simple.

18
00:00:51,424 --> 00:00:56,307
Concentrate needed equals your final tank
volume, times your target strength,

19
00:00:56,668 --> 00:00:58,449
divided by your stock strength.

20
00:00:59,089 --> 00:01:02,231
So twenty litres of three percent, from
fifteen percent hypo,

21
00:01:02,771 --> 00:01:05,393
is twenty times three, divided by fifteen.

22
00:01:07,214 --> 00:01:11,077
Four litres of hypo, and sixteen litres of
water and surfactant.

23
00:01:12,378 --> 00:01:13,578
Do the sum every time.

24
00:01:14,139 --> 00:01:17,141
And remember, old hypo isn't fifteen
percent any more.

25
00:01:17,581 --> 00:01:20,823
If it's sat in a hot van, your three
percent might be a lot less.

26
00:01:21,058 --> 00:01:22,039
Now, the portable trolley.

27
00:01:22,519 --> 00:01:25,042
Twenty five to fifty litres, a twelve volt
pump.

28
00:01:25,822 --> 00:01:30,106
Not glamorous, but brilliant for terraced
houses, courtyards and tight rear gardens.

29
00:01:31,287 --> 00:01:34,910
Imagine dragging fifty metres of chemical
hose down a side alley and through

30
00:01:34,950 --> 00:01:35,691
someone's living room.

31
00:01:36,852 --> 00:01:40,595
That's a trip hazard, a spill risk, and
you lose pressure to friction anyway.

32
00:01:41,176 --> 00:01:42,137
The trade-off is volume.

33
00:01:42,477 --> 00:01:43,418
You'll be refilling a lot.

34
00:01:43,662 --> 00:01:45,083
Then the static van tank.

35
00:01:45,083 --> 00:01:47,444
A hundred to three hundred litres or more.

36
00:01:48,105 --> 00:01:51,847
The big plus is honest, uniform chemistry
all the way down the hose.

37
00:01:52,407 --> 00:01:53,408
But think about weight.

38
00:01:53,848 --> 00:01:55,329
One litre is one kilo.

39
00:01:56,030 --> 00:02:00,492
Two hundred litres is two hundred kilos,
before you count the tank itself.

40
00:02:01,193 --> 00:02:04,054
Then there's surge, with all that liquid
sloshing when you brake.

41
00:02:04,715 --> 00:02:06,756
Hot vans degrade your hypo faster.

42
00:02:07,176 --> 00:02:11,459
And if the job finishes early, you're left
with corrosive mixed waste to deal with.

43
00:02:11,839 --> 00:02:13,040
That's the top-up trap again.

44
00:02:13,380 --> 00:02:16,342
Drain it and recalculate, never top up by
eye.