1
00:00:00,000 --> 00:00:03,760
If you're a window cleaner or a pressure
washing contractor thinking about adding

2
00:00:03,840 --> 00:00:07,520
softwashing, you've probably seen a van
build online and thought,

3
00:00:07,800 --> 00:00:10,800
I'd need five or ten grand just to get
started.

4
00:00:10,900 --> 00:00:15,200
Let's clear that one up, because it's the
single most common question I get,

5
00:00:15,220 --> 00:00:17,760
and it's holding people back for the wrong
reasons.

6
00:00:18,037 --> 00:00:20,357
I'm Mark Cave from SoftWash UK.

7
00:00:20,490 --> 00:00:25,157
In an earlier episode I talked about the
wider softwashing curriculum and why this

8
00:00:25,210 --> 00:00:28,277
trade is far more than a pump and a drum
of bleach.

9
00:00:28,384 --> 00:00:32,597
Today we're tackling one of those topics
head on: what equipment do you actually

10
00:00:32,661 --> 00:00:34,277
need to start softwashing?

11
00:00:34,383 --> 00:00:39,323
The myth is that you need complex van
builds, big proportioners and high capacity

12
00:00:39,387 --> 00:00:42,603
pump skids before you can take your first
paid job.

13
00:00:42,703 --> 00:00:46,443
The reality is that equipment without
method is a liability.

14
00:00:46,563 --> 00:00:51,403
Buy expensive kit before you understand
chemistry, surfaces and how application

15
00:00:51,473 --> 00:00:56,683
behaves, and you end up with wasted
capital, breakdowns, and sometimes damage to a

16
00:00:56,727 --> 00:00:57,883
customer's property.

17
00:00:58,123 --> 00:01:02,763
A simple, controlled setup you understand
will beat a flashy rig you don't.

18
00:01:02,900 --> 00:01:04,687
So let's build a starter blueprint.

19
00:01:04,834 --> 00:01:06,687
First, the delivery system.

20
00:01:06,887 --> 00:01:11,487
For domestic render, cladding and low
level work, you don't need a high end

21
00:01:11,531 --> 00:01:12,767
proportioning rig.

22
00:01:12,967 --> 00:01:15,807
A modest chemical compatible setup does
the job.

23
00:01:15,919 --> 00:01:21,087
That could be a 12 volt diaphragm pump
with Viton seals and Santoprene diaphragms,

24
00:01:21,287 --> 00:01:26,207
a dedicated application trolley, or even a
chemical rated manual applicator.

25
00:01:26,352 --> 00:01:28,392
Now here's the bit people get backwards.

26
00:01:28,504 --> 00:01:30,072
They chase power.

27
00:01:30,172 --> 00:01:34,952
But excessive pump flow creates runoff,
wasted chemical and overspray.

28
00:01:35,096 --> 00:01:36,872
What matters is control.

29
00:01:37,032 --> 00:01:42,712
You want low pressure delivery, under 100
PSI, with just enough flow to saturate the

30
00:01:42,812 --> 00:01:45,712
biofilm without blasting the surface.

31
00:01:45,816 --> 00:01:49,432
Softwashing is about chemistry doing the
work, not force.

32
00:01:49,563 --> 00:01:54,557
Second, and this catches out more
beginners than anything, is compatibility across

33
00:01:54,597 --> 00:01:55,717
the whole line.

34
00:01:55,780 --> 00:01:57,397
People think about the pump.

35
00:01:57,487 --> 00:02:00,157
But the pump is rarely the first thing to
fail.

36
00:02:00,357 --> 00:02:03,117
Fittings, hoses and valves go first.

37
00:02:03,254 --> 00:02:08,397
Sodium hypochlorite, and acidic cleaners
too, will quickly attack reactive metals

38
00:02:08,429 --> 00:02:11,037
like brass, aluminium and mild steel.

39
00:02:11,330 --> 00:02:16,397
So you want polypropylene, PVC, chemical
grade polyurethane,

40
00:02:16,450 --> 00:02:20,237
or good quality stainless steel at every
point the chemical touches.

41
00:02:20,250 --> 00:02:21,690
And carry spares.

42
00:02:21,783 --> 00:02:26,570
There's a saying I like: a two pound
fitting can stop a seven hundred pound job.

43
00:02:26,650 --> 00:02:30,410
Keep chemical resistant O rings, hose
joiners, jubilee clips,

44
00:02:30,530 --> 00:02:35,130
PTFE tape, spare nozzles, strainers and
replacement fuses in the van.

45
00:02:35,410 --> 00:02:39,210
A failed coupling on site should never
mean you abort a job and drive home.

46
00:02:39,502 --> 00:02:41,889
Third, nozzles.

47
00:02:42,038 --> 00:02:45,889
Please don't take your pressure washer and
spray softwash chemicals through it.

48
00:02:46,169 --> 00:02:51,489
A narrow tip at high pressure atomises the
chemical into a fine airborne mist.

49
00:02:51,569 --> 00:02:56,289
That mist drifts onto neighbours' cars,
gardens and people walking past.

50
00:02:56,368 --> 00:03:01,729
What you want is a wide fan, low pressure
nozzle, or a dedicated water fed pole

51
00:03:01,793 --> 00:03:02,769
softwash nozzle.

52
00:03:02,902 --> 00:03:07,729
These give you heavy, clinging droplets
that land on the surface and stay there,

53
00:03:07,763 --> 00:03:09,409
rather than floating off in the wind.

54
00:03:09,645 --> 00:03:14,079
Fourth, batch mixing versus inline
proportioners.

55
00:03:14,346 --> 00:03:19,599
My advice is to master batch mixing first,
in clean, calibrated containers.

56
00:03:19,799 --> 00:03:20,479
Why?

57
00:03:20,569 --> 00:03:23,759
Because it forces you to understand the
dilution maths.

58
00:03:23,899 --> 00:03:28,479
You start with stock sodium hypochlorite
at around 14 to 15 percent,

59
00:03:28,599 --> 00:03:30,719
and you work down to a surface strength.

60
00:03:30,799 --> 00:03:35,359
Typically that's one to three percent on
render, and up to four to six percent for

61
00:03:35,412 --> 00:03:37,039
heavy organic contamination.

62
00:03:37,252 --> 00:03:41,679
If you can't do that sum in your head on a
driveway, an injector won't save you.

63
00:03:41,896 --> 00:03:46,008
Once you move to an injector, like the
Dosatron systems we supply,

64
00:03:46,108 --> 00:03:46,968
calibrate it.

65
00:03:47,181 --> 00:03:49,688
Do a simple bucket test with clean water.

66
00:03:49,864 --> 00:03:54,408
Backpressure and hose friction can make
the ratio you actually deliver drift away

67
00:03:54,440 --> 00:03:55,928
from the number on the dial.

68
00:03:56,008 --> 00:03:58,328
Never assume the dial is telling the
truth.

69
00:03:58,578 --> 00:04:02,018
Fifth, and it's often forgotten, is water.

70
00:04:02,210 --> 00:04:05,458
Softwashing is not spray and walk away.

71
00:04:05,551 --> 00:04:07,938
Clean water management is half the job.

72
00:04:08,078 --> 00:04:12,818
You need reliable water delivery to pre
wet vegetation right down to the roots,

73
00:04:12,845 --> 00:04:16,738
to rinse window frames and glass, and to
flush your lines after use.

74
00:04:17,002 --> 00:04:19,629
Sixth, your own protection.

75
00:04:19,762 --> 00:04:24,509
Based on your COSHH assessment, that means
chemical resistant nitrile or neoprene

76
00:04:24,566 --> 00:04:29,549
gloves, safety goggles or a full face
shield, especially when you're mixing,

77
00:04:29,592 --> 00:04:32,189
transferring concentrate or working
overhead.

78
00:04:32,409 --> 00:04:37,229
Add chemical resistant coveralls or
waterproofs, chemical resistant footwear,

79
00:04:37,336 --> 00:04:40,429
an eyewash bottle and a proper spill kit.

80
00:04:40,541 --> 00:04:45,629
Most serious incidents happen while
handling and mixing, not while spraying a wall,

81
00:04:45,682 --> 00:04:46,749
so don't skimp here.

82
00:04:46,750 --> 00:04:49,070
Which brings me to the point under all of
this.

83
00:04:49,250 --> 00:04:54,510
The most expensive way to learn
softwashing is through trial and error on customers'

84
00:04:54,554 --> 00:04:55,150
properties.

85
00:04:55,550 --> 00:05:00,030
Do you know the difference between
monocouche and external wall insulation render?

86
00:05:00,206 --> 00:05:01,390
Lime render?

87
00:05:01,570 --> 00:05:02,910
Delicate stone?

88
00:05:03,123 --> 00:05:04,590
Coated roof tiles?

89
00:05:04,937 --> 00:05:08,990
Do you know why you must never mix acids
with sodium hypochlorite,

90
00:05:09,060 --> 00:05:10,910
because of the toxic gas risk?

91
00:05:11,257 --> 00:05:13,470
Do you know where your runoff is going?

92
00:05:13,694 --> 00:05:18,910
That knowledge comes before specialist
gear, because it tells you what to buy and

93
00:05:18,942 --> 00:05:19,710
what to ignore.

94
00:05:20,103 --> 00:05:22,530
So here's your practical action step.

95
00:05:22,690 --> 00:05:28,370
Decide what work you actually want to do
first, say domestic render and cladding.

96
00:05:28,543 --> 00:05:32,850
Build a small, compatible, understood
setup around that.

97
00:05:33,010 --> 00:05:35,090
Practise with clean water.

98
00:05:35,183 --> 00:05:36,850
Check your dilutions.

99
00:05:36,914 --> 00:05:40,130
Then upgrade based on real jobs, not
guesswork.

100
00:05:40,330 --> 00:05:45,290
Podcasts like this are a great starting
point, but if you're serious about offering

101
00:05:45,370 --> 00:05:50,810
softwashing professionally, the SoftWash
UK CPD Certified Softwash Training Course

102
00:05:50,917 --> 00:05:56,970
takes you much deeper into chemistry,
surfaces, safety, equipment and real world

103
00:05:57,030 --> 00:05:57,770
application.

104
00:05:58,143 --> 00:06:01,210
It's online, so you learn at your own
pace.

105
00:06:01,306 --> 00:06:06,730
Eligible CITB registered employers can
access up to 70 percent grant funding under

106
00:06:06,774 --> 00:06:08,330
Building Repair and Maintenance.

107
00:06:08,530 --> 00:06:13,210
And completing the certification leads to
recognition as an Approved Softwash

108
00:06:13,270 --> 00:06:17,770
Applicator, and membership of the National
Association of Softwash community.

109
00:06:18,047 --> 00:06:23,147
You'll find the training, plus
professional resources, equipment and chemicals,

110
00:06:23,227 --> 00:06:24,907
at softwashing.uk.

111
00:06:25,207 --> 00:06:29,307
The aim has always been to raise standards
in this industry,

112
00:06:29,327 --> 00:06:31,547
and it starts with knowledge before kit.

113
00:06:31,747 --> 00:06:34,867
Thanks for listening, and I'll catch you
in the next one.