1
00:00:00,100 --> 00:00:04,340
I got a call late Tuesday afternoon from a
contractor who was completely at his wits

2
00:00:04,420 --> 00:00:04,620
end.

3
00:00:06,220 --> 00:00:09,120
He was standing in front of a lovely new
monocouche render job,

4
00:00:09,520 --> 00:00:12,520
red algae everywhere, and he had already
been over it twice.

5
00:00:13,340 --> 00:00:17,940
He told me, Mark, I have got my
proportioning rig dialed in at three percent,

6
00:00:18,420 --> 00:00:20,300
but it is just not touching it.

7
00:00:21,040 --> 00:00:22,500
So I asked him one simple question.

8
00:00:23,460 --> 00:00:25,840
Have you actually measured what is coming
out of the nozzle,

9
00:00:26,280 --> 00:00:28,100
or are you just reading the sticker on the
dial?

10
00:00:29,115 --> 00:00:31,155
And there was this long pause on the
phone.

11
00:00:32,375 --> 00:00:36,015
You see, he was running 50 metres of half
inch hose off his van.

12
00:00:36,755 --> 00:00:40,115
By the time that mix traveled through
fifty metres of friction and backpressure,

13
00:00:40,555 --> 00:00:43,975
his actual output at the tip was under one
percent active strength.

14
00:00:44,595 --> 00:00:47,775
He thought he was hitting it with three
percent, but he was barely giving it a

15
00:00:47,815 --> 00:00:48,135
rinse.

16
00:00:48,895 --> 00:00:52,195
And that right there is the classic trap
with proportioning systems.

17
00:00:52,770 --> 00:00:53,670
Now, don't get me wrong.

18
00:00:53,790 --> 00:00:55,390
I, I, I love proportioning gear.

19
00:00:55,830 --> 00:00:59,970
Systems like the Dosatron or the Clever
Injector are incredible bits of kit.

20
00:01:00,470 --> 00:01:03,570
They save you time, they save you from
lugging heavy tanks around,

21
00:01:04,070 --> 00:01:06,750
and they stop you from constantly
measuring out liquid on site.

22
00:01:07,650 --> 00:01:08,490
But here is the thing.

23
00:01:09,370 --> 00:01:13,010
They trade simple mental calculations for
system complexity.

24
00:01:13,787 --> 00:01:17,587
When you batch mix, say you make up a 100
litre batch in a dedicated tank.

25
00:01:18,247 --> 00:01:22,107
If you put sixteen litres of water and
four litres of fifteen percent sodium

26
00:01:22,147 --> 00:01:26,967
hypochlorite in that container, you know
for a absolute fact that you have got a

27
00:01:27,027 --> 00:01:27,967
three percent mix.

28
00:01:28,607 --> 00:01:30,787
The chemistry in that tank cannot lie to
you.

29
00:01:31,367 --> 00:01:34,827
It does not matter if your hose is ten
metres long or one hundred metres long,

30
00:01:35,327 --> 00:01:37,567
the strength in the tank remains three
percent.

31
00:01:38,420 --> 00:01:41,580
With an inline proportioner, you are
relying on fluid physics.

32
00:01:42,160 --> 00:01:45,780
Line friction, small hose internal
diameters like half inch,

33
00:01:46,260 --> 00:01:50,600
high flow rates, and even the thick
viscosity of cold chemical will create

34
00:01:50,700 --> 00:01:51,260
backpressure.

35
00:01:52,060 --> 00:01:56,000
That backpressure restricts how much
concentrate the manifold can physically draw

36
00:01:56,080 --> 00:01:56,240
up.

37
00:01:56,880 --> 00:02:00,740
So while your dial face says three
percent, the physics at the end of your lance

38
00:02:00,780 --> 00:02:03,100
might only be delivering one percent or
less.

39
00:02:03,980 --> 00:02:06,460
You are essentially working blind unless
you check it.

40
00:02:06,705 --> 00:02:10,125
And look, I am not pointing fingers here.

41
00:02:10,684 --> 00:02:14,365
I have made every single mistake in the
book over the years.

42
00:02:15,065 --> 00:02:19,165
I remember back in my early days, I used
to batch mix by eye when I was in a rush.

43
00:02:19,745 --> 00:02:23,985
I would have half a tank left over from a
driveway job, and I would just splash in

44
00:02:24,025 --> 00:02:27,445
another couple of gallons of hypo and top
it up with the garden hose.

45
00:02:28,165 --> 00:02:29,865
I thought I was being efficient.

46
00:02:30,467 --> 00:02:35,187
In reality, I was pushing what should have
been a safe two percent render mix right

47
00:02:35,267 --> 00:02:36,607
up to four percent or higher.

48
00:02:37,427 --> 00:02:41,127
I was burning through my profit margins by
wasting expensive concentrate,

49
00:02:41,587 --> 00:02:46,507
and even worse, I was risking severe
chemical burn on the homeowner's prize rose

50
00:02:46,547 --> 00:02:48,087
bushes from heavy runoff.

51
00:02:49,207 --> 00:02:53,927
Guesswork in this line of work always
costs you money, whether it is in wasted

52
00:02:53,967 --> 00:02:55,807
chemical or damaged property.

53
00:02:56,915 --> 00:03:00,555
So how do you make sure your equipment is
actually delivering what you think it is?

54
00:03:01,215 --> 00:03:06,055
It comes down to a dead simple routine I
call the 60 second bucket test.

55
00:03:07,115 --> 00:03:10,175
Before you unpack fifty metres of hose on
a commercial site,

56
00:03:10,655 --> 00:03:14,995
grab a calibrated one litre measuring jug
and a clean five litre bucket.

57
00:03:15,970 --> 00:03:20,250
Set your proportioner to your target
strength, run your system for a few seconds to

58
00:03:20,290 --> 00:03:23,530
prime the line, and then fill that jug
straight from the nozzle.

59
00:03:24,390 --> 00:03:28,430
If you are aiming for a two percent active
application strength from a fifteen

60
00:03:28,510 --> 00:03:33,290
percent stock drum, your actual mix ratios
need to align precisely in that jug.

61
00:03:34,210 --> 00:03:38,710
Testing output at the tip takes literally
one minute, but it guarantees that you are

62
00:03:38,770 --> 00:03:42,270
not under treating the building or dumping
cash down the drain.

63
00:03:43,312 --> 00:03:47,792
Another huge mistake I see contractors
make with proportioners is the sequence of

64
00:03:47,852 --> 00:03:48,752
adding additives.

65
00:03:49,712 --> 00:03:53,632
Always introduce your bleach compatible
surfactant, like Clever Wash,

66
00:03:54,052 --> 00:03:55,192
into the mix correctly.

67
00:03:56,072 --> 00:04:00,432
If you draw heavy, neat surfactant
directly through certain proportioning valves

68
00:04:00,832 --> 00:04:06,312
without proper dilution or mixing
sequences, you can create air locks or sticky gel

69
00:04:06,412 --> 00:04:09,252
blockages inside the delicate internal
seals.

70
00:04:10,210 --> 00:04:14,830
Using a proper softwash surfactant is
essential because it breaks surface tension

71
00:04:15,110 --> 00:04:18,450
and creates that rich, controlled cling on
vertical render,

72
00:04:18,870 --> 00:04:20,870
fascias, and powder coated cladding.

73
00:04:21,770 --> 00:04:26,410
That extra hang time means the chemistry
stays on the organic stain doing its job

74
00:04:26,850 --> 00:04:28,810
rather than sloughing off onto the ground.

75
00:04:29,550 --> 00:04:32,910
But you have got to respect how the
equipment handles those additives.

76
00:04:33,083 --> 00:04:37,163
I want every contractor listening to adopt
a quick pre flight checklist before

77
00:04:37,216 --> 00:04:38,923
starting any job.

78
00:04:38,990 --> 00:04:43,243
First, check your raw stock strength with
a hydrometer or test strip,

79
00:04:43,273 --> 00:04:46,123
because old bleach degrades rapidly in hot
weather.

80
00:04:46,283 --> 00:04:51,163
Second, run your bucket test at the nozzle
to confirm your real world delivery.

81
00:04:51,283 --> 00:04:55,323
And third, always carry out a hidden test
patch on a small,

82
00:04:55,385 --> 00:04:59,803
discreet fifty millimetre area before you
put together your final quote.

83
00:05:00,023 --> 00:05:04,530
At the end of the day, having a flashy van
setup with expensive pumps and polished

84
00:05:04,570 --> 00:05:08,130
dials does not automatically make you a
professional.

85
00:05:08,226 --> 00:05:12,610
Real authority in this industry comes from
understanding substrate physics,

86
00:05:12,666 --> 00:05:16,290
mastering your chemical ratios, and
protecting your customer's building.

87
00:05:16,592 --> 00:05:20,645
If you want to step up your technical
skills, learn safe compliance,

88
00:05:20,685 --> 00:05:25,605
and stand out from the splash and dash
operators, head over to softwashing.uk.

89
00:05:25,701 --> 00:05:30,565
Take a look at our CPD Certified Softwash
Training Course and get yourself listed on

90
00:05:30,585 --> 00:05:33,205
our Approved Softwash Applicator
directory.

91
00:05:33,354 --> 00:05:38,565
Master the science, protect your margins,
and I will catch you on the next episode.