1
00:00:00,060 --> 00:00:03,644
The number on your Dosatron dial is not
the number on the wall.

2
00:00:04,905 --> 00:00:08,909
I'll say that again, because it catches
out more contractors than almost anything

3
00:00:08,969 --> 00:00:09,230
else.

4
00:00:10,151 --> 00:00:14,795
The dial says twenty five percent, and
plenty of people hear that and think they're

5
00:00:14,815 --> 00:00:16,878
spraying a twenty five percent solution.

6
00:00:17,538 --> 00:00:17,999
They're not.

7
00:00:18,439 --> 00:00:19,180
Not even close.

8
00:00:19,432 --> 00:00:24,217
I'm Mark Cave from SoftWash UK, and today
we're going inside the Clever Injector

9
00:00:24,257 --> 00:00:24,797
Dosatron.

10
00:00:25,298 --> 00:00:29,422
How it works, how to dial in your recipes,
and the discipline that keeps it

11
00:00:29,502 --> 00:00:29,942
accurate.

12
00:00:31,304 --> 00:00:35,848
If you listened to my earlier episode on
dilution ratios versus applied percentages,

13
00:00:36,428 --> 00:00:39,792
this is where that maths turns into
something you do on site.

14
00:00:40,205 --> 00:00:41,246
First, the mechanism.

15
00:00:41,806 --> 00:00:42,667
It's water powered.

16
00:00:43,788 --> 00:00:45,329
No electrics, no battery.

17
00:00:46,009 --> 00:00:50,552
The water flowing through the unit drives
a piston inside, and that piston pulls

18
00:00:50,612 --> 00:00:54,475
concentrate up from your container and
injects it into the water stream.

19
00:00:55,236 --> 00:00:58,438
The dial simply sets how much concentrate
is drawn per stroke.

20
00:00:59,238 --> 00:01:02,541
So the dial setting is the percentage of
concentrate in the final mix,

21
00:01:03,181 --> 00:01:07,324
and that concentrate is already at
fourteen to fifteen percent if you're using neat

22
00:01:07,424 --> 00:01:08,425
sodium hypochlorite.

23
00:01:08,625 --> 00:01:10,182
Now do the sum.

24
00:01:10,182 --> 00:01:16,020
Set the dial to twenty five percent, and
you've got twenty five percent of a

25
00:01:16,020 --> 00:01:17,966
fourteen to fifteen percent product.

26
00:01:17,966 --> 00:01:23,414
That lands you at roughly three and a half
to four percent applied strength.

27
00:01:23,414 --> 00:01:27,306
Set it to twenty, and you're at about
three percent.

28
00:01:27,306 --> 00:01:32,366
Fourteen gives you around two percent, two
point one if you're being precise.

29
00:01:32,366 --> 00:01:35,090
And seven gives you roughly one percent.

30
00:01:35,090 --> 00:01:37,425
Four dial settings, four real recipes.

31
00:01:37,558 --> 00:01:38,178
What do they suit?

32
00:01:38,699 --> 00:01:42,121
The twenty five setting, around four
percent, is for rough concrete,

33
00:01:42,501 --> 00:01:46,263
heavy growth on concrete roof tiles and
heavily colonised block driveways.

34
00:01:47,164 --> 00:01:51,626
Twenty, around three percent, is for
render, brickwork, glazed roof tiles,

35
00:01:51,986 --> 00:01:53,888
pool surrounds and standard block paving.

36
00:01:54,908 --> 00:01:59,911
Fourteen, around two percent, covers
heavily stained UPVC, industrial cladding,

37
00:02:00,251 --> 00:02:03,013
painted surfaces, timber fencing and
tarmac.

38
00:02:03,893 --> 00:02:08,416
And seven, around one percent, is for
delicate surfaces, maintenance cleans,

39
00:02:08,736 --> 00:02:11,498
and light film on soffits, gutters and
painted cladding.

40
00:02:11,745 --> 00:02:12,226
One caution.

41
00:02:12,766 --> 00:02:16,109
Those figures assume your stock really is
fourteen to fifteen percent.

42
00:02:17,631 --> 00:02:20,994
Sodium hypochlorite weakens with age, heat
and sunlight.

43
00:02:21,614 --> 00:02:25,358
If your drum is old, your dial setting is
telling a story that isn't true.

44
00:02:26,198 --> 00:02:30,262
Verify your stock strength, and always
test patch before you commit to a whole

45
00:02:30,302 --> 00:02:30,803
elevation.

46
00:02:31,283 --> 00:02:33,165
Knowledge first, product second.

47
00:02:33,250 --> 00:02:34,079
Now, biocide.

48
00:02:34,079 --> 00:02:36,982
This is where people get into trouble.

49
00:02:36,982 --> 00:02:43,201
Products like Soft Wash Pro 50 are highly
concentrated, and you apply them at low

50
00:02:43,201 --> 00:02:44,030
finished ratios.

51
00:02:44,030 --> 00:02:48,591
Twenty five to one, which is roughly a two
percent solution,

52
00:02:48,591 --> 00:02:51,494
or fifty to one, roughly one percent.

53
00:02:51,494 --> 00:02:56,055
But the Dosatron's range runs from five to
twenty five percent.

54
00:02:56,055 --> 00:03:02,274
So if you draw neat biocide through it,
even at the bottom of the dial,

55
00:03:02,274 --> 00:03:03,933
you're massively over applying.

56
00:03:03,933 --> 00:03:07,250
Wasted product, wasted money, and not
better cleaning.

57
00:03:07,290 --> 00:03:09,071
The answer is pre dilution.

58
00:03:09,651 --> 00:03:14,074
Take one litre of Soft Wash Pro 50 and mix
it into four litres of water.

59
00:03:14,735 --> 00:03:18,457
Or five litres into twenty, which fills a
twenty five litre drum.

60
00:03:19,237 --> 00:03:20,658
That drum is your stock.

61
00:03:22,319 --> 00:03:26,542
Then for roofs and render, a two percent
recipe at twenty five to one,

62
00:03:27,062 --> 00:03:28,503
set the injector to four to one.

63
00:03:29,503 --> 00:03:32,906
For maintenance cleaning, a one percent
recipe at fifty to one,

64
00:03:33,386 --> 00:03:34,486
set it to nine to one.

65
00:03:36,688 --> 00:03:38,469
Pre dilute first, then dial.

66
00:03:39,009 --> 00:03:40,130
Never the other way round.

67
00:03:40,392 --> 00:03:43,414
Next, the bit I'd ask you to treat as non
negotiable.

68
00:03:43,834 --> 00:03:45,475
The sixty second bucket test.

69
00:03:46,756 --> 00:03:51,119
Long hose runs, fifty to a hundred metres,
a climb up onto a high roof,

70
00:03:51,739 --> 00:03:52,520
a tight nozzle.

71
00:03:53,300 --> 00:03:57,283
All of that creates backpressure, and
backpressure can make your injection drift

72
00:03:57,323 --> 00:03:58,644
away from what the dial says.

73
00:03:59,464 --> 00:04:04,207
So take a graduated measuring cylinder,
draw from it into a bucket for sixty seconds

74
00:04:04,327 --> 00:04:07,709
at your real working pressure, and see how
much actually goes in.

75
00:04:09,070 --> 00:04:09,851
It takes a minute.

76
00:04:10,411 --> 00:04:11,752
It can save you a roof.

77
00:04:11,997 --> 00:04:13,258
Mind the operating limits too.

78
00:04:13,718 --> 00:04:16,540
Flow from one point six to thirty three
litres a minute.

79
00:04:16,941 --> 00:04:19,122
Pressure from half a bar to four bar.

80
00:04:19,843 --> 00:04:22,225
Three quarter inch BSP male connections.

81
00:04:22,685 --> 00:04:24,726
Water no hotter than forty degrees.

82
00:04:25,647 --> 00:04:30,088
If site mains flow is weak or fluctuating,
a booster pump, like a one inch self

83
00:04:30,088 --> 00:04:32,492
priming stainless steel unit, steadies
things.

84
00:04:33,012 --> 00:04:34,453
And fit the bypass upgrade.

85
00:04:35,714 --> 00:04:39,157
It lets you switch to clean water for
rinsing without pulling any chemical.

86
00:04:39,475 --> 00:04:40,496
And then there's maintenance.

87
00:04:41,237 --> 00:04:46,482
Sodium hypochlorite that dries and
crystallises will wreck your Viton and EPDM seals

88
00:04:46,602 --> 00:04:47,704
and jam the piston.

89
00:04:48,184 --> 00:04:52,649
So after every single job, run clean water
through the suction hose.

90
00:04:53,089 --> 00:04:53,990
Every job.

91
00:04:54,451 --> 00:04:58,234
It costs you a couple of minutes, and it
protects a unit that's well over a thousand

92
00:04:58,255 --> 00:04:58,595
pounds.

93
00:04:58,850 --> 00:05:03,092
A Dosatron gives you consistency, less
chemical to carry and less waste.

94
00:05:03,693 --> 00:05:05,094
But it doesn't give you judgement.

95
00:05:05,734 --> 00:05:09,736
Knowing the surface, the stock strength
and the right recipe is what makes it

96
00:05:09,756 --> 00:05:10,297
professional.

97
00:05:11,117 --> 00:05:14,519
Podcasts like this are a great start, but
if you're serious about offering

98
00:05:14,599 --> 00:05:20,022
softwashing properly, the CPD Certified
Softwash Training Course at softwashing dot

99
00:05:20,022 --> 00:05:24,745
uk goes much deeper into dilution,
equipment setup, safety and application,

100
00:05:25,205 --> 00:05:25,966
at your own pace.

101
00:05:27,086 --> 00:05:31,369
It also opens the door to becoming an
Approved Softwash Applicator and joining the

102
00:05:31,409 --> 00:05:33,410
National Association of Softwash
community.

103
00:05:33,727 --> 00:05:35,250
Here's a challenge before your next job.

104
00:05:35,991 --> 00:05:40,619
Do the bucket test, write down what you
actually get, and compare it to the dial.

105
00:05:41,260 --> 00:05:42,362
You might be surprised.

106
00:05:43,344 --> 00:05:45,187
Take care, and speak to you again soon.