1
00:00:00,120 --> 00:00:02,060
You get a call from a contractor, right?

2
00:00:02,320 --> 00:00:06,720
And he is absolutely convinced his
chemical supplier sold him a bad batch.

3
00:00:07,420 --> 00:00:11,980
He says, Mark, I dumped a ten percent
sodium hypochlorite mix onto this render,

4
00:00:12,480 --> 00:00:13,820
and it is totally patchy.

5
00:00:14,300 --> 00:00:19,360
The algae is still there in stripes, it
looks a mess, the chemical is useless.

6
00:00:20,220 --> 00:00:23,800
But nine times out of ten, when I actually
get on site or look at the video,

7
00:00:24,240 --> 00:00:25,840
the sodium hypochlorite was fine.

8
00:00:26,380 --> 00:00:28,820
The active chemistry was perfectly potent.

9
00:00:29,460 --> 00:00:30,560
The problem was delivery.

10
00:00:31,257 --> 00:00:33,637
If your delivery fails, your clean fails.

11
00:00:33,997 --> 00:00:35,177
It is as simple as that.

12
00:00:35,897 --> 00:00:39,637
If you are spraying droplets that bead up
and roll straight off the elevation in

13
00:00:39,677 --> 00:00:43,457
three seconds flat, it does not matter if
you have got a hot mix in your tank.

14
00:00:43,957 --> 00:00:47,557
The active ingredients simply do not have
the contact time to break down the

15
00:00:47,597 --> 00:00:48,157
biofilm.

16
00:00:48,657 --> 00:00:52,777
The chemical cannot clean if you cannot
deliver it properly and hold it where the

17
00:00:52,797 --> 00:00:53,857
contamination lives.

18
00:00:54,702 --> 00:00:58,682
Think about what happens when somebody
uses a standard pressure washer with a high

19
00:00:58,802 --> 00:01:01,822
pressure pencil jet or a narrow tip to
apply chemicals.

20
00:01:02,382 --> 00:01:06,282
You get massive atomisation, severe
chemical drift in the wind,

21
00:01:06,702 --> 00:01:10,662
and you are hitting that delicate render
or cladding with aggressive mechanical

22
00:01:10,822 --> 00:01:11,162
force.

23
00:01:11,762 --> 00:01:16,102
That narrow jet strips surface finishes,
it scars soft render,

24
00:01:16,542 --> 00:01:20,382
and it drives water directly behind
cladding joints and into wall vents.

25
00:01:21,022 --> 00:01:25,282
That is not softwashing, that is just high
pressure blasting with an expensive

26
00:01:25,362 --> 00:01:26,782
chemical hazard added to it.

27
00:01:27,383 --> 00:01:31,403
What you actually want is a wide,
controlled low pressure fan nozzle.

28
00:01:32,063 --> 00:01:35,443
A proper fan pattern delivers uniform
coverage at low pressure.

29
00:01:35,963 --> 00:01:40,463
It lays a consistent film of liquid across
the substrate without forcing moisture

30
00:01:40,503 --> 00:01:42,023
into places it should never go.

31
00:01:42,623 --> 00:01:46,663
And when you are applying chemicals to
vertical render, here is a rule you need to

32
00:01:46,743 --> 00:01:51,623
etch into your mind: work from the bottom
upwards when applying to vertical render

33
00:01:51,983 --> 00:01:53,523
to reduce heavy run marks.

34
00:01:54,503 --> 00:01:56,423
I see guys start at the top all the time.

35
00:01:56,983 --> 00:02:00,903
The chemical runs down a dry, porous wall
in uneven streams,

36
00:02:01,323 --> 00:02:05,843
creating dark chemical channels that are a
complete nightmare to blend out later.

37
00:02:06,563 --> 00:02:10,383
When you start at the bottom and work your
way up, the solution hits an already

38
00:02:10,503 --> 00:02:14,663
wetted surface as you climb, preventing
those harsh vertical run lines.

39
00:02:14,995 --> 00:02:19,195
Now, even with the right nozzle and the
right direction, plain chemical mix can

40
00:02:19,355 --> 00:02:23,875
still bead up like water on a freshly
waxed car, especially on modern silicone

41
00:02:23,915 --> 00:02:26,355
renders like K Rend or powder coated
cladding.

42
00:02:26,995 --> 00:02:29,455
That is where a bleach stable surfactant
comes in.

43
00:02:29,975 --> 00:02:33,875
Adding a proper surfactant, like our
Clever Wash, completely breaks the surface

44
00:02:33,935 --> 00:02:34,775
tension of the liquid.

45
00:02:35,335 --> 00:02:39,275
Instead of droplets bouncing off or
cascading straight into the drainage channels,

46
00:02:39,735 --> 00:02:42,575
the mix transforms into an even, clinging
film.

47
00:02:43,195 --> 00:02:47,215
It stays on the elevation, giving you
maximum dwell time so the chemistry can do the

48
00:02:47,295 --> 00:02:48,035
actual work.

49
00:02:49,378 --> 00:02:52,518
I remember a contractor a while back
working on a commercial cladding site.

50
00:02:53,098 --> 00:02:56,298
Brilliant lad, hard worker, but he was
struggling big time.

51
00:02:56,898 --> 00:03:01,098
He had burned through three full tanks of
a strong ten percent hypo mix on a single

52
00:03:01,138 --> 00:03:04,618
elevation, and the cladding still looked
streaky and half cleaned.

53
00:03:05,178 --> 00:03:06,998
He was ready to walk off the job in tears.

54
00:03:07,598 --> 00:03:08,738
I took one look at his rig.

55
00:03:09,258 --> 00:03:13,078
He was trying to push product up forty
feet using a standard high pressure lance,

56
00:03:13,478 --> 00:03:17,738
blasting half his chemical into the sky
while the rest just ran off the slick metal

57
00:03:17,858 --> 00:03:19,778
paneling in thin, vertical rivulets.

58
00:03:20,455 --> 00:03:24,715
We swapped that lance out right there on
site for a proper water fed pole softwash

59
00:03:24,835 --> 00:03:25,495
nozzle setup.

60
00:03:26,155 --> 00:03:29,015
We dialed down the pressure, added Clever
Wash to the tank,

61
00:03:29,375 --> 00:03:33,295
and applied a controlled, low pressure fan
spray across the panels from ground

62
00:03:33,335 --> 00:03:33,575
level.

63
00:03:34,175 --> 00:03:37,455
We used less than half a tank for the
entire remaining elevation,

64
00:03:37,895 --> 00:03:42,095
the cling was perfect, and the cladding
cleaned up uniformly in fifteen minutes.

65
00:03:42,715 --> 00:03:44,375
Same chemical, same strength.

66
00:03:44,835 --> 00:03:47,135
The only thing that changed was the
delivery method.

67
00:03:47,993 --> 00:03:51,593
That brings us to how you match your
application gear to the specific substrate you

68
00:03:51,613 --> 00:03:52,093
are treating.

69
00:03:52,733 --> 00:03:57,033
You cannot use a one size fits all mindset
in professional exterior cleaning.

70
00:03:57,673 --> 00:04:02,453
A smooth UPVC fascia needs a completely
different delivery flow rate than a rough,

71
00:04:02,613 --> 00:04:05,513
porous concrete roof tile or a delicate
stone wall.

72
00:04:06,297 --> 00:04:10,857
For larger elevations, having a dedicated
low pressure pump skid or a proportional

73
00:04:10,957 --> 00:04:14,997
dosing system like the Clever Injector
Dosatron makes an enormous difference.

74
00:04:15,777 --> 00:04:20,137
A Dosatron allows you to pull clean water
and chemical concentrate simultaneously,

75
00:04:20,717 --> 00:04:25,397
calibrating your exact final application
percentage on the fly without batch mixing

76
00:04:25,436 --> 00:04:26,157
giant tanks.

77
00:04:26,917 --> 00:04:30,957
You maintain a rock solid chemical to
water ratio whether you are spraying ten

78
00:04:31,017 --> 00:04:35,137
litres a minute on a vast commercial
warehouse or turning it down for detailed

79
00:04:35,217 --> 00:04:36,077
residential work.

80
00:04:36,410 --> 00:04:40,070
Calibration is also about site control and
managing environmental risks.

81
00:04:40,730 --> 00:04:42,730
Every single property presents hazards.

82
00:04:43,290 --> 00:04:47,430
Before you pull a spray trigger anywhere
near a building, you have got to manage

83
00:04:47,530 --> 00:04:48,430
overspray and drift.

84
00:04:49,310 --> 00:04:50,650
Are there prize garden beds below?

85
00:04:51,390 --> 00:04:55,290
Pre wet all surrounding foliage with clean
water before, during,

86
00:04:55,490 --> 00:04:56,630
and after application.

87
00:04:57,350 --> 00:05:01,190
Keep the plants hydrated so their roots
absorb fresh water rather than chemical

88
00:05:01,250 --> 00:05:01,610
runoff.

89
00:05:02,730 --> 00:05:05,190
Are you working near a car park or a
public pavement?

90
00:05:05,930 --> 00:05:09,009
Set up clear exclusion zones and check the
wind direction.

91
00:05:09,869 --> 00:05:13,029
And watch your spray angles, especially on
roofs.

92
00:05:13,909 --> 00:05:16,209
Never spray upwards under the tile laps.

93
00:05:16,969 --> 00:05:20,009
Roof tiles are designed to shed water
downwards with gravity.

94
00:05:20,629 --> 00:05:25,009
If you aim a spray lance upwards under the
laps, you force chemical solution

95
00:05:25,109 --> 00:05:28,469
directly under the tiles, where it can
saturate the timber battens,

96
00:05:28,869 --> 00:05:32,069
rot the underlay membrane, or leak
straight into the loft space.

97
00:05:33,049 --> 00:05:37,149
Always aim your fan pattern down the pitch
or parallel to the tiles.

98
00:05:38,238 --> 00:05:42,018
This level of attention to detail is what
separates a true professional from a

99
00:05:42,078 --> 00:05:43,318
splash and dash operator.

100
00:05:44,078 --> 00:05:47,558
It is about risk assessments, site
specific RAMS paperwork,

101
00:05:47,978 --> 00:05:51,438
COSHH compliance, and knowing your
equipment inside and out.

102
00:05:52,418 --> 00:05:58,098
That is why we built the SoftWash UK CPD
Certified Softwash Training Course and our

103
00:05:58,138 --> 00:06:00,178
Approved Softwash Applicator status.

104
00:06:01,078 --> 00:06:05,298
We want UK contractors to have the
technical confidence, safety standards,

105
00:06:05,618 --> 00:06:10,698
and practical knowledge to deliver
flawless results safely on every single property.

106
00:06:11,800 --> 00:06:15,900
So before you head out onto your next job,
take ten minutes to audit your delivery

107
00:06:15,980 --> 00:06:16,360
setup.

108
00:06:17,080 --> 00:06:17,900
Check your nozzles.

109
00:06:18,420 --> 00:06:18,960
Are they worn?

110
00:06:19,740 --> 00:06:21,220
Are you using the right fan angle?

111
00:06:21,960 --> 00:06:23,340
Is your surfactant dialed in?

112
00:06:24,100 --> 00:06:25,820
Are your pumps calibrated correctly?

113
00:06:26,600 --> 00:06:29,300
Do not just blame the chemical when a
clean goes wrong.

114
00:06:30,020 --> 00:06:31,100
Master your delivery.

115
00:06:32,400 --> 00:06:35,880
If you want to level up your gear, dive
deeper into application methods,

116
00:06:36,340 --> 00:06:40,440
or earn your recognized accreditation,
head over to softwashing.uk.

117
00:06:41,120 --> 00:06:44,840
We have got all the specialized
application equipment, professional chemicals,

118
00:06:45,140 --> 00:06:49,380
and accredited training resources you need
to build a elite exterior cleaning

119
00:06:49,400 --> 00:06:49,820
business.

120
00:06:50,740 --> 00:06:54,420
Thanks for listening today, stay safe on
site, know your chemistry,

121
00:06:54,780 --> 00:06:56,040
and I will catch you on the next one.