1
00:00:00,000 --> 00:00:04,240
When a render clean goes wrong, what's the
first thing most contractors say?

2
00:00:04,380 --> 00:00:06,080
The bleach must have been weak.

3
00:00:06,320 --> 00:00:08,560
Or, the bleach must have been too strong.

4
00:00:08,686 --> 00:00:10,960
Either way, they blame the chemical.

5
00:00:11,173 --> 00:00:14,080
In my experience, that's rarely where the
problem sits.

6
00:00:14,200 --> 00:00:15,920
The problem is delivery.

7
00:00:16,107 --> 00:00:20,320
It's how that chemical got from the drum
to the wall, and whether you actually knew

8
00:00:20,368 --> 00:00:21,760
what strength you were putting on.

9
00:00:22,220 --> 00:00:26,740
I'm Mark Cave from SoftWash UK, and today
we're comparing batch mixing with

10
00:00:26,784 --> 00:00:28,020
proportioning systems.

11
00:00:28,380 --> 00:00:32,580
A while back I said new contractors should
master batch mixing in calibrated

12
00:00:32,631 --> 00:00:36,420
containers first, because it forces you to
learn the dilution maths.

13
00:00:36,553 --> 00:00:38,260
Today is the next step.

14
00:00:38,404 --> 00:00:42,820
What are your options, what do they cost
you, and when does it make sense to move

15
00:00:42,900 --> 00:00:43,140
on?

16
00:00:43,442 --> 00:00:46,262
Let's start with why this matters.

17
00:00:46,342 --> 00:00:50,822
When operators eyeball a drum, or top up a
half empty tank on site,

18
00:00:50,868 --> 00:00:53,782
concentration errors can swing by up to 40
percent.

19
00:00:53,915 --> 00:00:55,142
Think about that.

20
00:00:55,302 --> 00:01:00,342
Too weak, and the algae survives, the
render dries patchy, and you're back on site

21
00:01:00,422 --> 00:01:01,342
unpaid.

22
00:01:01,452 --> 00:01:06,262
Too strong, and you're wasting expensive
chemical, scorching planting and risking

23
00:01:06,308 --> 00:01:07,902
streaks on the surface.

24
00:01:07,990 --> 00:01:09,942
Same chemical, same drum.

25
00:01:10,029 --> 00:01:12,222
Completely different outcome.

26
00:01:12,420 --> 00:01:15,167
So here's how proper batch mixing works.

27
00:01:15,287 --> 00:01:17,007
You measure your water first.

28
00:01:17,151 --> 00:01:21,887
Then you add your concentrate, say sodium
hypochlorite at 14 to 15 percent,

29
00:01:22,047 --> 00:01:23,167
or a biocide.

30
00:01:23,343 --> 00:01:26,527
Then the bleach compatible surfactant goes
in last.

31
00:01:26,687 --> 00:01:31,887
Clever Wash, for example, runs at 200 to
1, which is 5 millilitres per litre.

32
00:01:32,067 --> 00:01:33,567
And the maths is simple.

33
00:01:33,681 --> 00:01:38,447
Target strength, divided by stock
strength, multiplied by your final volume.

34
00:01:38,580 --> 00:01:44,607
Three percent from a 15 percent stock,
making 20 litres, is 4 litres of hypochlorite

35
00:01:44,667 --> 00:01:46,367
and 16 litres of water.

36
00:01:46,543 --> 00:01:51,487
Know your stock strength, because drums
vary and hypochlorite weakens with age.

37
00:01:51,677 --> 00:01:54,450
Batch mixing comes in two main forms.

38
00:01:54,570 --> 00:01:56,850
First, the portable trolley.

39
00:01:56,930 --> 00:02:01,730
That's a dedicated 12 volt battery
trolley, usually 25 to 50 litres,

40
00:02:01,762 --> 00:02:02,930
with Viton seals.

41
00:02:03,143 --> 00:02:07,330
It's brilliant for rear gardens,
courtyards and domestic bungalows.

42
00:02:07,530 --> 00:02:08,210
Why?

43
00:02:08,300 --> 00:02:12,850
Because dragging a long hose run through a
house or round a tight property costs you

44
00:02:12,930 --> 00:02:15,650
flow through friction, and causes
disruption.

45
00:02:15,810 --> 00:02:18,690
The outlay is low and it's very agile.

46
00:02:18,850 --> 00:02:20,770
The trade off is capacity.

47
00:02:20,890 --> 00:02:22,370
You'll be refilling a lot.

48
00:02:22,375 --> 00:02:24,135
The second is the static van tank.

49
00:02:24,242 --> 00:02:29,575
We're talking 100 to 300 litres or more,
paired with a 12 volt diaphragm pump,

50
00:02:29,607 --> 00:02:31,575
something like a Remco or a Flojet.

51
00:02:31,735 --> 00:02:33,735
The big advantage is honesty.

52
00:02:33,948 --> 00:02:38,295
If you've calculated that tank accurately
from scratch, the chemistry in it cannot

53
00:02:38,375 --> 00:02:40,135
lie, regardless of hose length.

54
00:02:40,275 --> 00:02:41,575
But think about the weight.

55
00:02:41,775 --> 00:02:44,295
One litre of water is one kilo.

56
00:02:44,495 --> 00:02:49,415
A 200 litre tank adds 200 kilos of liquid,
plus the tank, to your payload.

57
00:02:49,555 --> 00:02:53,015
Add sloshing on corners, hypochlorite
breaking down in a hot van,

58
00:02:53,104 --> 00:02:57,335
leftover mix going to waste when a job
finishes early, and the downtime when it runs

59
00:02:57,435 --> 00:02:59,175
dry halfway across an elevation.

60
00:02:59,382 --> 00:03:01,522
And that brings me to the top up trap.

61
00:03:01,632 --> 00:03:02,642
Picture it.

62
00:03:02,762 --> 00:03:04,242
You start with a full tank.

63
00:03:04,349 --> 00:03:05,922
By lunchtime it's half gone.

64
00:03:06,062 --> 00:03:09,762
You grab a container of hypochlorite, tip
in what feels about right,

65
00:03:09,822 --> 00:03:11,602
top up with the hose, and carry on.

66
00:03:11,742 --> 00:03:13,042
You haven't drained it.

67
00:03:13,122 --> 00:03:14,562
You haven't recalculated.

68
00:03:14,702 --> 00:03:17,442
Now the strength is a guess, and it's
probably higher.

69
00:03:17,582 --> 00:03:21,042
The top of the wall looks brilliant, the
lower section is streaked,

70
00:03:21,082 --> 00:03:22,722
and the landscaping is paying for it.

71
00:03:22,850 --> 00:03:26,002
That's how a decent morning turns into an
expensive callback.

72
00:03:26,215 --> 00:03:27,955
Now, proportioning.

73
00:03:28,115 --> 00:03:30,115
Let's go through the options honestly.

74
00:03:30,248 --> 00:03:33,075
First, the downstream venturi injector.

75
00:03:33,182 --> 00:03:37,475
These are inexpensive, and they pull
chemical in after a pressure washer pump.

76
00:03:37,539 --> 00:03:39,155
They're fine for light detergents.

77
00:03:39,295 --> 00:03:42,035
But for controlled softwashing they're
inaccurate.

78
00:03:42,163 --> 00:03:46,915
Draw rates shift with hose length,
elevation, tip size and any drop in water

79
00:03:46,959 --> 00:03:47,395
pressure.

80
00:03:47,535 --> 00:03:51,795
Maximum draw ratios typically hover below
10 to 20 percent,

81
00:03:51,848 --> 00:03:55,475
so high strength render or roof
applications simply aren't possible.

82
00:03:55,589 --> 00:03:58,515
Change your nozzle and your strength
changes with it.

83
00:03:58,779 --> 00:04:01,035
Next, the proportioning manifold.

84
00:04:01,147 --> 00:04:06,075
That's a three way valve block metering
water, neat hypochlorite and surfactant into

85
00:04:06,115 --> 00:04:07,035
a 12 volt pump.

86
00:04:07,248 --> 00:04:10,155
It removes the hold tank, so no payload
problem.

87
00:04:10,315 --> 00:04:14,955
But backpressure, line friction, think 50
metres of half inch hose,

88
00:04:14,995 --> 00:04:18,715
and the thickness of the surfactant can
all make the real output drift away from the

89
00:04:18,765 --> 00:04:19,835
numbers on the dial.

90
00:04:19,875 --> 00:04:22,515
Then there's the water powered hydraulic
injector.

91
00:04:22,595 --> 00:04:25,155
That's your Dosatron, or the Clever
Injector.

92
00:04:25,342 --> 00:04:26,435
No electricity.

93
00:04:26,515 --> 00:04:30,915
The water flow drives an internal piston,
which draws concentrate straight from the

94
00:04:30,959 --> 00:04:34,435
original container into the water line at
a percentage you set.

95
00:04:34,648 --> 00:04:36,035
It mixes on demand.

96
00:04:36,142 --> 00:04:38,595
Close the trigger, and the draw stops
instantly.

97
00:04:38,715 --> 00:04:42,115
You're not carrying hundreds of litres of
corrosive mixed liquid.

98
00:04:42,302 --> 00:04:47,395
It can cut chemical waste by up to 25
percent, and it makes COSHH records simpler,

99
00:04:47,435 --> 00:04:50,115
because you're recording a setting, not a
guess.

100
00:04:50,215 --> 00:04:51,635
The downsides are real, though.

101
00:04:51,735 --> 00:04:56,275
The entry price is higher, roughly £500 to
£1,600 and above.

102
00:04:56,435 --> 00:04:59,075
You need adequate water supply pressure.

103
00:04:59,155 --> 00:05:01,075
And you must calibrate it routinely.

104
00:05:01,239 --> 00:05:03,695
That calibration point is critical.

105
00:05:03,740 --> 00:05:07,335
Turning the dial to three percent does not
mean three percent lands on the wall.

106
00:05:07,548 --> 00:05:10,295
So do the 60 second bucket test.

107
00:05:10,395 --> 00:05:13,415
Run your chemical intake from a graduated
measuring container,

108
00:05:13,511 --> 00:05:17,015
with your hose at its real working length,
for 60 seconds.

109
00:05:17,135 --> 00:05:21,095
Measure how many millilitres were drawn
against the total water volume.

110
00:05:21,202 --> 00:05:23,735
If it's off, adjust and test again.

111
00:05:23,842 --> 00:05:28,215
It takes a minute, and it happens before
any chemical touches a customer's building.

112
00:05:28,427 --> 00:05:30,600
So which system should you choose?

113
00:05:30,673 --> 00:05:32,160
Match it to your business stage.

114
00:05:32,280 --> 00:05:35,920
Start with a simple batch trolley or tank
you fully understand.

115
00:05:35,987 --> 00:05:38,880
Learn the dilution maths, learn site
control.

116
00:05:38,976 --> 00:05:43,600
Then scale into calibrated Dosatron setups
when commercial speed and repeatability

117
00:05:43,657 --> 00:05:44,080
matter.

118
00:05:44,220 --> 00:05:48,800
And remember, commercial work, facilities
management contracts and high ticket

119
00:05:48,844 --> 00:05:53,200
domestic jobs need proper RAMS, site
specific COSHH assessments,

120
00:05:53,340 --> 00:05:56,080
pre wetting of vegetation and drainage
control.

121
00:05:56,192 --> 00:05:58,560
Equipment doesn't replace any of that.

122
00:05:58,648 --> 00:06:02,000
Knowledge comes before products, every
time.

123
00:06:02,077 --> 00:06:06,087
Podcasts like this are a great starting
point, but if you're serious about offering

124
00:06:06,167 --> 00:06:11,287
softwashing professionally, the SoftWash
UK CPD Certified Softwash Training Course

125
00:06:11,399 --> 00:06:13,087
goes much deeper.

126
00:06:13,145 --> 00:06:19,047
Delivery systems, calibration, surface
science, safety, all built from years of real

127
00:06:19,087 --> 00:06:22,567
world experience, and you learn online at
your own pace.

128
00:06:22,647 --> 00:06:26,887
Completing it opens the door to becoming
an Approved Softwash Applicator,

129
00:06:26,903 --> 00:06:30,647
with a directory listing and a place in
the National Association of Softwash

130
00:06:30,703 --> 00:06:31,647
community.

131
00:06:31,735 --> 00:06:37,047
Eligible CITB registered employers can
also claim up to 70 percent grant funding

132
00:06:37,140 --> 00:06:39,127
under Building Repair and Maintenance.

133
00:06:39,271 --> 00:06:41,607
Have a look at softwashing.uk.

134
00:06:41,625 --> 00:06:42,505
Here's my challenge.

135
00:06:42,718 --> 00:06:47,865
On your next job, run that 60 second
bucket test, or if you batch mix,

136
00:06:47,945 --> 00:06:50,025
recalculate instead of topping up by eye.

137
00:06:50,158 --> 00:06:51,865
Write down what you find.

138
00:06:52,005 --> 00:06:53,465
You might be surprised.

139
00:06:53,602 --> 00:06:56,346
Thanks for listening, and I'll catch you
in the next one.