1
00:00:00,280 --> 00:00:05,460
You are on a job, say you are looking at a
rendered wall or a piece of natural

2
00:00:05,559 --> 00:00:09,960
stone, and you see two distinct problems
right in front of you.

3
00:00:10,300 --> 00:00:14,340
You have got black spot, biological
contamination on one side,

4
00:00:14,920 --> 00:00:18,180
and then right next to it, or maybe
running down from a fixing,

5
00:00:18,719 --> 00:00:21,919
you have got a stubborn brown rust stain.

6
00:00:22,699 --> 00:00:27,479
And the, the, the thought pops into your
head, well, why not just mix my sodium

7
00:00:27,519 --> 00:00:32,799
hypochlorite with my oxalic acid stain
remover in one tank?

8
00:00:32,880 --> 00:00:36,659
One pass, job done, save an hour on site,
right?

9
00:00:38,399 --> 00:00:43,259
I am telling you now, that single thought
is how contractors end up in hospital,

10
00:00:43,719 --> 00:00:47,159
and it is how jobs get evacuated by
emergency services.

11
00:00:47,407 --> 00:00:51,307
Let us look at what actually happens
chemically when you do that,

12
00:00:51,887 --> 00:00:56,447
because this is not just a case of two
chemicals not playing nicely together.

13
00:00:57,027 --> 00:01:02,708
Sodium hypochlorite, your standard hypo,
sits at an alkaline pH of around 12 to 13.

14
00:01:03,287 --> 00:01:09,327
Oxalic acid, or any acidic rust remover or
descaler, sits down at a pH of 1 to 2.

15
00:01:10,048 --> 00:01:13,927
When you combine an alkali that high with
an acid that low,

16
00:01:14,507 --> 00:01:16,548
you do not get a super cleaner.

17
00:01:16,968 --> 00:01:22,228
You get a violent neutralization reaction
that instantly liberates toxic chlorine

18
00:01:22,267 --> 00:01:23,208
gas into the air.

19
00:01:23,867 --> 00:01:25,807
I mean, literally instantly.

20
00:01:26,119 --> 00:01:30,019
That cloud of green yellow gas hits your
lungs, it hits your eyes,

21
00:01:30,400 --> 00:01:34,420
and it causes immediate severe respiratory
trauma, burning,

22
00:01:34,760 --> 00:01:37,139
coughing, and total panic on site.

23
00:01:37,659 --> 00:01:41,659
And here is the kicker for anyone who
thinks they are being clever and saving time.

24
00:01:42,219 --> 00:01:46,600
The acid destroys the hypo, and the hypo
neutralizes the acid.

25
00:01:47,100 --> 00:01:50,239
So you are left with zero cleaning
capability on the surface.

26
00:01:50,719 --> 00:01:55,019
You have destroyed your active chemical
agents, you have corroded your pump seals

27
00:01:55,059 --> 00:01:59,459
and equipment fittings in seconds, and you
have created a massive health and safety

28
00:01:59,540 --> 00:02:01,139
liability on your client's property.

29
00:02:01,719 --> 00:02:04,959
It is the ultimate myth that mixing them
gives you extra power.

30
00:02:05,161 --> 00:02:08,441
I remember a situation a few years back
with a contractor I was speaking to.

31
00:02:09,001 --> 00:02:13,641
He had been out doing a job, and he had
not checked his Safety Data Sheets properly.

32
00:02:14,221 --> 00:02:18,841
Even worse, he had used a shared measuring
jug on his van, first for an acidic rust

33
00:02:18,901 --> 00:02:23,722
remover, and then straight into a drum of
concentrated 14 to 15 percent sodium

34
00:02:23,781 --> 00:02:25,882
hypochlorite without washing it out.

35
00:02:26,562 --> 00:02:29,741
He put the lid back on, tossed the drum in
the back of the transit van,

36
00:02:30,021 --> 00:02:31,621
and started driving to his next job.

37
00:02:33,101 --> 00:02:37,341
Within ten minutes, the residual acid in
that jug had triggered off gassing inside

38
00:02:37,382 --> 00:02:38,381
the sealed container.

39
00:02:39,001 --> 00:02:42,021
Pressure built up, chemical fumes filled
the back of the van,

40
00:02:42,321 --> 00:02:46,421
and he had to pull over on a busy road,
eyes streaming, gasping for air,

41
00:02:46,781 --> 00:02:49,402
having to call emergency services to
secure the vehicle.

42
00:02:50,301 --> 00:02:52,681
That was pure luck that he managed to pull
over safely.

43
00:02:53,361 --> 00:02:56,722
All because of a failure to check the SDS
and segregate his gear.

44
00:02:56,951 --> 00:03:01,692
So how do we actually handle jobs where
both organic biological growth and inorganic

45
00:03:01,792 --> 00:03:02,792
rust staining are present?

46
00:03:03,571 --> 00:03:06,632
It comes down to one strict rule in
professional softwashing,

47
00:03:07,011 --> 00:03:09,491
and that is the two stage application
rule.

48
00:03:10,212 --> 00:03:15,371
You never, ever let acid and hypochlorite
meet on a surface or in a system.

49
00:03:16,351 --> 00:03:19,792
If you are treating algae or black spot
first with sodium hypochlorite,

50
00:03:20,231 --> 00:03:24,111
you apply your mix, allow your dwell time,
and then you rinse that surface

51
00:03:24,231 --> 00:03:26,451
thoroughly with low pressure clean water.

52
00:03:27,151 --> 00:03:31,251
And I do not mean a quick splash, I mean a
complete, deep rinse.

53
00:03:32,031 --> 00:03:36,771
Then, crucially, you allow the surface to
dry before you even think about bringing

54
00:03:36,851 --> 00:03:40,351
out an acidic product like oxalic acid to
treat the metal stains.

55
00:03:40,641 --> 00:03:43,022
The same discipline applies to your
equipment on the van.

56
00:03:43,242 --> 00:03:45,502
You need total chemical segregation.

57
00:03:45,881 --> 00:03:49,581
That means dedicated, color coded
measuring jugs and funnels for acids,

58
00:03:50,002 --> 00:03:52,301
completely separate from your softwash
bleach kit.

59
00:03:52,922 --> 00:03:56,121
Every container must be clearly labeled
under COSHH guidelines.

60
00:03:56,701 --> 00:04:01,521
If you are using proportioner systems or
Dosatron setups, you never run acid through

61
00:04:01,581 --> 00:04:06,001
lines that have held hypo without doing a
complete, thorough clean water flush of

62
00:04:06,021 --> 00:04:07,542
the entire manifold first.

63
00:04:08,421 --> 00:04:11,061
Keeping those systems separated is what
protects your pumps,

64
00:04:11,501 --> 00:04:15,261
your hoses, and your staff from
catastrophic off gassing events.

65
00:04:15,492 --> 00:04:18,833
Now, when you understand this chemistry
and you build these controls into your

66
00:04:18,872 --> 00:04:22,632
business, something interesting happens to
your commercial prospects.

67
00:04:23,412 --> 00:04:26,052
When you walk onto a commercial site,
whether it is a school,

68
00:04:26,352 --> 00:04:31,333
a care home, or a property managed block,
facilities managers do not want a cowboy

69
00:04:31,372 --> 00:04:34,192
who turns up with unlabelled drums and
guesses his mix.

70
00:04:34,853 --> 00:04:38,632
When you hand them site specific RAMS,
proper COSHH assessments detailing your

71
00:04:38,673 --> 00:04:42,292
chemical storage, exposure controls, and
emergency procedures,

72
00:04:42,692 --> 00:04:46,152
you instantly separate yourself from
nineties percent of the competition.

73
00:04:46,327 --> 00:04:51,108
That professional credibility is what
allows you to charge professional rates and

74
00:04:51,168 --> 00:04:53,327
win high margin commercial contracts.

75
00:04:54,067 --> 00:04:58,687
It is why we put so much emphasis on
education at softwashing.uk.

76
00:04:59,747 --> 00:05:04,148
Completing our CPD Certified Softwash
Training Course and getting listed on the

77
00:05:04,308 --> 00:05:08,888
Approved Softwash Applicator directory
proves to clients that you understand

78
00:05:08,987 --> 00:05:13,347
chemical safety, legal compliance, and
real world application.

79
00:05:14,367 --> 00:05:19,068
Stop guessing, treat the chemistry with
respect, keep your products segregated,

80
00:05:19,487 --> 00:05:23,767
and build a business based on standards,
safety, and real knowledge.

81
00:05:25,388 --> 00:05:28,408
Safe washing out there, and I will catch
you on the next one.